Percutaneous intraluminal downsizing of systemic‐to‐pulmonary artery shunts: a novel application of the Diabolo stent technique—Case series and description of the technique. Issue 3 (19th November 2019)
- Record Type:
- Journal Article
- Title:
- Percutaneous intraluminal downsizing of systemic‐to‐pulmonary artery shunts: a novel application of the Diabolo stent technique—Case series and description of the technique. Issue 3 (19th November 2019)
- Main Title:
- Percutaneous intraluminal downsizing of systemic‐to‐pulmonary artery shunts: a novel application of the Diabolo stent technique—Case series and description of the technique
- Authors:
- Maschietto, Nicola
Baird, Christopher
Porras, Diego - Abstract:
- Abstract: Objective: This article aims to describe the feasibility of a novel application of the Diabolo stent technique for percutaneous downsizing of systemic‐to‐pulmonary artery shunts in patients with pulmonary overcirculation. Background: Pulmonary overcirculation can lead to systemic hypoperfusion, impaired systemic oxygen delivery, and hemodynamic instability especially in patients with single‐ventricle physiology. Different medical and surgical strategies to treat pulmonary overcirculation have been reported so far, but no percutaneous approach amenable to further adjustment over time has been described. Methods: Retrospective review of patients who underwent percutaneous intraluminal reduction of a systemic‐to‐pulmonary artery shunt with a covered stent in a Diabolo "hour‐glass" configuration. Results: From July 2018 to February 4, 2019, consecutive patients underwent trans‐catheter downsizing of a systemic‐to‐pulmonary artery shunt. The median age was 3.3 years (range 0.7–5.7 years). All patients had symptomatic pulmonary overflow despite maximal medical therapy. All patients underwent successful implantation of a covered stent in a Diabolo "hour‐glass" configuration without any complications. Successful reduction in pulmonary overcirculation was noted in all patients with a decrease of mean pulmonary artery pressure from a median of 29 mmHg (range 25–32 mmHg) to a median of 21 mmHg (range 14–27 mmHg). Conclusions: Percutaneous intraluminal downsizing ofAbstract: Objective: This article aims to describe the feasibility of a novel application of the Diabolo stent technique for percutaneous downsizing of systemic‐to‐pulmonary artery shunts in patients with pulmonary overcirculation. Background: Pulmonary overcirculation can lead to systemic hypoperfusion, impaired systemic oxygen delivery, and hemodynamic instability especially in patients with single‐ventricle physiology. Different medical and surgical strategies to treat pulmonary overcirculation have been reported so far, but no percutaneous approach amenable to further adjustment over time has been described. Methods: Retrospective review of patients who underwent percutaneous intraluminal reduction of a systemic‐to‐pulmonary artery shunt with a covered stent in a Diabolo "hour‐glass" configuration. Results: From July 2018 to February 4, 2019, consecutive patients underwent trans‐catheter downsizing of a systemic‐to‐pulmonary artery shunt. The median age was 3.3 years (range 0.7–5.7 years). All patients had symptomatic pulmonary overflow despite maximal medical therapy. All patients underwent successful implantation of a covered stent in a Diabolo "hour‐glass" configuration without any complications. Successful reduction in pulmonary overcirculation was noted in all patients with a decrease of mean pulmonary artery pressure from a median of 29 mmHg (range 25–32 mmHg) to a median of 21 mmHg (range 14–27 mmHg). Conclusions: Percutaneous intraluminal downsizing of systemic‐to‐pulmonary artery shunts with a covered stent in a Diabolo configuration is safe and feasible. With this technique, the pulmonary blood flow can be adjusted in a physiologic closed‐chest condition and further regulated over time. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 95:Issue 3(2020)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 95:Issue 3(2020)
- Issue Display:
- Volume 95, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 95
- Issue:
- 3
- Issue Sort Value:
- 2020-0095-0003-0000
- Page Start:
- 471
- Page End:
- 476
- Publication Date:
- 2019-11-19
- Subjects:
- congenital heart disease -- covered stent -- Diabolo stent -- pulmonary overcirculation
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.28598 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: