Auto regulatory capacity of the thyroid gland after numerous iodinated contrast media investigations. (2nd April 2020)
- Record Type:
- Journal Article
- Title:
- Auto regulatory capacity of the thyroid gland after numerous iodinated contrast media investigations. (2nd April 2020)
- Main Title:
- Auto regulatory capacity of the thyroid gland after numerous iodinated contrast media investigations
- Authors:
- Bøhmer, Thomas
Bachtyari, Zivar
Sommer, Christine
Hammerstad, Sara Salehi - Abstract:
- Abstract: Excess of iodine may interfere with thyroid function. It is unclear to what extent the thyroid function is disturbed by repeated infusion of iodide contrast agent (IC) used during X-ray examinations. Thyroid function tests free T4 (FT4), free FT3 (FT3), thyroid-stimulating hormone (TSH), TSH receptor antibodies (TRAb) and thyroid peroxidase antibodies (TPO-Ab) were measured in a group of Norwegian patients with an assumed normal iodine balance before, 1 and 6 weeks after IC infusion. Forty patients (19 females and 21 men) referred for routine CT were included. Thirty two out of 40 patients had previously undertaken IC investigations. The mean TSH concentration was 2.1 mIU/l ± 1.7 at the baseline, increased to 2.9 ± 2.5 after 1 week ( p < .001), and reverted to nearly initial values 1.4 ± 0.8 after 6 weeks. Initially the mean FT4 was 14.1 pmol/l ± 1.9 FT4, reduced to 13.3 pmol/l ± 2.5 ( p = .009) after 1 week, and returned to 14.0 pmol/l ± 2.5 after 6 weeks, comparable to the initial values ( p > .05). FT3 levels did not change during the period. There was no relationship between FT4, or TSH and age, gender, cancer/not cancer, number or frequency of earlier IC investigations. In conclusion, IC induces changes in thyroid function tests, however, they return to normal levels after 6 weeks. Our results suggest adequate auto regulatory capacity of the thyroid gland even in those with repeated contrast investigations (up to 40). Routine testing of thyroid functionAbstract: Excess of iodine may interfere with thyroid function. It is unclear to what extent the thyroid function is disturbed by repeated infusion of iodide contrast agent (IC) used during X-ray examinations. Thyroid function tests free T4 (FT4), free FT3 (FT3), thyroid-stimulating hormone (TSH), TSH receptor antibodies (TRAb) and thyroid peroxidase antibodies (TPO-Ab) were measured in a group of Norwegian patients with an assumed normal iodine balance before, 1 and 6 weeks after IC infusion. Forty patients (19 females and 21 men) referred for routine CT were included. Thirty two out of 40 patients had previously undertaken IC investigations. The mean TSH concentration was 2.1 mIU/l ± 1.7 at the baseline, increased to 2.9 ± 2.5 after 1 week ( p < .001), and reverted to nearly initial values 1.4 ± 0.8 after 6 weeks. Initially the mean FT4 was 14.1 pmol/l ± 1.9 FT4, reduced to 13.3 pmol/l ± 2.5 ( p = .009) after 1 week, and returned to 14.0 pmol/l ± 2.5 after 6 weeks, comparable to the initial values ( p > .05). FT3 levels did not change during the period. There was no relationship between FT4, or TSH and age, gender, cancer/not cancer, number or frequency of earlier IC investigations. In conclusion, IC induces changes in thyroid function tests, however, they return to normal levels after 6 weeks. Our results suggest adequate auto regulatory capacity of the thyroid gland even in those with repeated contrast investigations (up to 40). Routine testing of thyroid function should therefore not be undertaken in this patient group. … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 80:Number 3(2020)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 80:Number 3(2020)
- Issue Display:
- Volume 80, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 80
- Issue:
- 3
- Issue Sort Value:
- 2020-0080-0003-0000
- Page Start:
- 191
- Page End:
- 195
- Publication Date:
- 2020-04-02
- Subjects:
- Hypothyroidism -- hyperthyroidism -- thyroid function -- iodine supply -- iodine contrast media exposures
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365513.2019.1709658 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13633.xml