Development of raw acceleration cut-points for wrist and hip accelerometers to assess sedentary behaviour and physical activity in 5–7-year-old children. Issue 9 (2nd May 2020)
- Record Type:
- Journal Article
- Title:
- Development of raw acceleration cut-points for wrist and hip accelerometers to assess sedentary behaviour and physical activity in 5–7-year-old children. Issue 9 (2nd May 2020)
- Main Title:
- Development of raw acceleration cut-points for wrist and hip accelerometers to assess sedentary behaviour and physical activity in 5–7-year-old children
- Authors:
- Crotti, Matteo
Foweather, Lawrence
Rudd, James R.
Hurter, Liezel
Schwarz, Sebastian
Boddy, Lynne M. - Abstract:
- ABSTRACT: This study validated sedentary behaviour (SB), moderate-to-vigorous physical activity (MVPA) and vigorous physical activity (VPA) accelerometer cut-points in 5–7-year-old children. Participants (n = 49, 55% girls) wore an ActiGraph GT9X accelerometer, recording data at 100 Hz downloaded in 1 s epochs, on both wrists and the right hip during a standardised protocol and recess. Cut-points were generated using ROC analysis with direct observation as a criterion. Subsequently, cut-points were optimised using Confidence intervals equivalency analysis and then cross-validated in a cross-validation group. SB cut-points were 36 mg (Sensitivity (Sn) = 79.8%, Specificity (Sp) = 56.8%) for non-dominant wrist, 39 mg (Sn = 75.4%, Sp = 70.2%) for dominant wrist and 20 mg (Sn = 78%, Sp = 50.1%) for hip. MVPA cut-points were 189 mg (Sn = 82.6%, Sp = 78%) for non-dominant wrist, 181 mg (Sn = 79.1%, Sp = 76%) for dominant wrist and 95 mg (Sn = 79.3%, Sp = 75.6%) for hip. VPA cut-points were 536 mg (Sn = 75.1%, Sp = 68.7%) for non-dominant wrist, 534 mg (Sn = 67.6%, Sp = 95.6%) for dominant wrist and 325 mg (Sn = 78.2%, Sp = 96.1%) for hip. All placements demonstrated adequate levels of accuracy for SB and PA assessment.
- Is Part Of:
- Journal of sports sciences. Volume 38:Issue 9(2020)
- Journal:
- Journal of sports sciences
- Issue:
- Volume 38:Issue 9(2020)
- Issue Display:
- Volume 38, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 38
- Issue:
- 9
- Issue Sort Value:
- 2020-0038-0009-0000
- Page Start:
- 1036
- Page End:
- 1045
- Publication Date:
- 2020-05-02
- Subjects:
- Accelerometry -- validation -- raw signal -- objective measurement -- criterion validity
Sports -- Periodicals
Sports -- Physiological aspects -- Periodicals
Sports -- Psychological aspects -- Periodicals
612.044 - Journal URLs:
- http://www.tandfonline.com/toc/rjsp20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/02640414.2020.1740469 ↗
- Languages:
- English
- ISSNs:
- 0264-0414
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5066.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13641.xml