Assessment of stress/strain in dental implants and abutments of alternative materials compared to conventional titanium alloy—3D non-linear finite element analysis. Issue 8 (10th June 2020)
- Record Type:
- Journal Article
- Title:
- Assessment of stress/strain in dental implants and abutments of alternative materials compared to conventional titanium alloy—3D non-linear finite element analysis. Issue 8 (10th June 2020)
- Main Title:
- Assessment of stress/strain in dental implants and abutments of alternative materials compared to conventional titanium alloy—3D non-linear finite element analysis
- Authors:
- Tretto, Pedro Henrique Wentz
dos Santos, Mateus Bertolini Fernandes
Spazzin, Aloisio Oro
Pereira, Gabriel Kalil Rocha
Bacchi, Atais - Abstract:
- Abstract: The aim of this study was to assess the stress/strain in dental implant/abutments with alternative materials, in implants with different microgeometry, through finite element analysis (FEA). Three-dimensional models were created to simulate the clinical situation of replacement of a maxillary central incisor with implants, in a type III bone, with a provisional single crown, loaded with 100 N in a perpendicular direction. The FEA parameters studied were: implant materials—titanium, porous titanium, titanium-zirconia, zirconia, reinforced fiberglass composite (RFC), and polyetheretherketone (PEEK); and abutment materials—titanium, zirconia, RFC, and PEEK; implant macrogeometry—tapered of trapezoidal threads (TTT) and cylindrical of triangular threads (CTT) (ø4.3 mm × 11 mm). Microstrain, von Mises, shear, and maximum and minimum principal stresses in the structures and in peri-implant bone were compared. There was increased stress and strain in peri-implant bone tissue caused by implants of materials with lower elastic modulus (mainly for PEEK and RFC). They also presented higher concentration of stresses in the implant itself (especially RFC). Zirconia implants led to lower stress and strains in peri-implant bone tissue. Less rigid abutments (RFC and PEEK) associated with titanium implants led to higher stress in the implant and in peri-implant bone tissue. The TTT macrogeometry showed a higher stress concentration in the implant and peri-implant bone tissue. TheAbstract: The aim of this study was to assess the stress/strain in dental implant/abutments with alternative materials, in implants with different microgeometry, through finite element analysis (FEA). Three-dimensional models were created to simulate the clinical situation of replacement of a maxillary central incisor with implants, in a type III bone, with a provisional single crown, loaded with 100 N in a perpendicular direction. The FEA parameters studied were: implant materials—titanium, porous titanium, titanium-zirconia, zirconia, reinforced fiberglass composite (RFC), and polyetheretherketone (PEEK); and abutment materials—titanium, zirconia, RFC, and PEEK; implant macrogeometry—tapered of trapezoidal threads (TTT) and cylindrical of triangular threads (CTT) (ø4.3 mm × 11 mm). Microstrain, von Mises, shear, and maximum and minimum principal stresses in the structures and in peri-implant bone were compared. There was increased stress and strain in peri-implant bone tissue caused by implants of materials with lower elastic modulus (mainly for PEEK and RFC). They also presented higher concentration of stresses in the implant itself (especially RFC). Zirconia implants led to lower stress and strains in peri-implant bone tissue. Less rigid abutments (RFC and PEEK) associated with titanium implants led to higher stress in the implant and in peri-implant bone tissue. The TTT macrogeometry showed a higher stress concentration in the implant and peri-implant bone tissue. The stress/strain in peri-implant bone tissue and implant structures were affected by the material used, where reduced values were caused by stiffer materials. Lower stress/strain values were obtained with cylindrical implants of triangular treads. … (more)
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 23:Issue 8(2020)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 23:Issue 8(2020)
- Issue Display:
- Volume 23, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 23
- Issue:
- 8
- Issue Sort Value:
- 2020-0023-0008-0000
- Page Start:
- 372
- Page End:
- 383
- Publication Date:
- 2020-06-10
- Subjects:
- Finite element analysis -- dental implants -- titanium -- stress -- strain -- mechanical phenomena
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2020.1731481 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13708.xml