Comparative analysis for five fixations of Pauwels-I by the biomechanical finite-element method. Issue 5 (27th May 2020)
- Record Type:
- Journal Article
- Title:
- Comparative analysis for five fixations of Pauwels-I by the biomechanical finite-element method. Issue 5 (27th May 2020)
- Main Title:
- Comparative analysis for five fixations of Pauwels-I by the biomechanical finite-element method
- Authors:
- Jian-Qiao Peng, Matthew
Chen, Hai-Yan
Ju, XiangYang
Hu, Yong
Ayoub, Ashraf
Khambay, Balvinder
Liu, ZiQing
Bai, Bo - Abstract:
- Abstract: Background: Little is known about how biomechanics govern the five fixtures such as DHS, MLS, DHS + LS, LP, and HA are accepted as common therapeutic techniques. Aims and objectives: A series of numerical models for a femoral neck fracture of Pauwels-I will be constructed by innovative approach of finite element in order to determine the most optimized option in comparison with biomechanical performance. Method: Twenty sets of computer tomography scanned femora were imported onto Mimics to extract 3 D models; these specimens were transferred to Geomagic-Studio for a simulative osteotomy and kyrtograph; then, they underwent UG to fit simulative solid models; 5 sorts of fixture were then expressed by Pro-Engineer virtually. After processing with HyperMesh, all compartments (fracture model + internal implant) were assembled onto 5 systems: "Dynamic Hip Screw (DHS), Multiple Lag screw (MLS), DHS + LS, femoral Locking Plate (LP) and HemiArthroplasty (HA)." Eventually, numerical models of the finite-elemental analysis were exported to AnSys to determine the solution. Result: Four models of fixation and a simulation of HA for Pauwels-I were established, validated, and analyzed with the following findings: In term of displacement, these 5 fixtures ranged between 0.3801 and 0.7536 mm have no significant difference; in term of stress, the averages of peaks for integral assemblage are b(MLS) = 43.5766 ≈< d(LP) = 43.6657 ≈<Abstract: Background: Little is known about how biomechanics govern the five fixtures such as DHS, MLS, DHS + LS, LP, and HA are accepted as common therapeutic techniques. Aims and objectives: A series of numerical models for a femoral neck fracture of Pauwels-I will be constructed by innovative approach of finite element in order to determine the most optimized option in comparison with biomechanical performance. Method: Twenty sets of computer tomography scanned femora were imported onto Mimics to extract 3 D models; these specimens were transferred to Geomagic-Studio for a simulative osteotomy and kyrtograph; then, they underwent UG to fit simulative solid models; 5 sorts of fixture were then expressed by Pro-Engineer virtually. After processing with HyperMesh, all compartments (fracture model + internal implant) were assembled onto 5 systems: "Dynamic Hip Screw (DHS), Multiple Lag screw (MLS), DHS + LS, femoral Locking Plate (LP) and HemiArthroplasty (HA)." Eventually, numerical models of the finite-elemental analysis were exported to AnSys to determine the solution. Result: Four models of fixation and a simulation of HA for Pauwels-I were established, validated, and analyzed with the following findings: In term of displacement, these 5 fixtures ranged between 0.3801 and 0.7536 mm have no significant difference; in term of stress, the averages of peaks for integral assemblage are b(MLS) = 43.5766 ≈< d(LP) = 43.6657 ≈< e(Ha) = 43.6657 < c(DHS + LS) = 66.5494 < a(DHS) = 105.617 in MPa indicate that MLS, LP and HA are not significantly different, but less than DHS + LS or DHS in each. Conclusion : A fixture of MLS or LP with optional HA should be recommended to clinically optimize a Pauwels-I facture. … (more)
- Is Part Of:
- Journal of investigative surgery. Volume 33:Issue 5(2020)
- Journal:
- Journal of investigative surgery
- Issue:
- Volume 33:Issue 5(2020)
- Issue Display:
- Volume 33, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 33
- Issue:
- 5
- Issue Sort Value:
- 2020-0033-0005-0000
- Page Start:
- 428
- Page End:
- 437
- Publication Date:
- 2020-05-27
- Subjects:
- Pauwels-I -- stress -- displacement -- fixation -- FEA
Surgery -- Research -- Periodicals
Research
Surgery
Surgical Procedures, Operative
617.075 - Journal URLs:
- http://informahealthcare.com/loi/ivs ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/08941939.2018.1533054 ↗
- Languages:
- English
- ISSNs:
- 0894-1939
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5008.020000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13618.xml