Monte-Carlo simulations with mathematical phantoms to investigate the effectiveness of a whole-body counter for thyroid measurement. (July 2020)
- Record Type:
- Journal Article
- Title:
- Monte-Carlo simulations with mathematical phantoms to investigate the effectiveness of a whole-body counter for thyroid measurement. (July 2020)
- Main Title:
- Monte-Carlo simulations with mathematical phantoms to investigate the effectiveness of a whole-body counter for thyroid measurement
- Authors:
- Tani, Kotaro
Igarashi, Yu
Kim, Eunjoo
Iimoto, Takeshi
Kurihara, Osamu - Abstract:
- Abstract: FASTSCAN (Canberra, Meriden, CT, USA), a standing-type whole-body counter with upper and lower NaI(Tl) detectors, has been mostly used to determine local residents' level of internal contamination with 134/137 Cs following the Fukushima Daiichi Nuclear Power Plant (FDNPP) disaster in 2011. In the present study, we performed Monte-Carlo simulations with age-specific mathematical human phantoms to investigate the counting efficiencies of the FASTSCAN counter for 131 I thyroid measurements. As a result, although the lower detector had low sensitivity for 131 I in the thyroids of the adult and 15 y phantoms as well as the 10 y phantom standing on a 30-cm-high stool, the response of this detector may be used as an indicator of surface contamination overlooked on a subject. The total counting efficiency investigated in this study was 0.017–0.018 (cps/Bq) among all age groups. Based on this sensitivity, the determination level for thyroid activity could be calculated to be ~300 Bq under the slightly elevated background radiation level observed after the FDNPP disaster. Highlights: The present study investigated the counting efficiencies of the whole-body counter called FASTSCAN for 131 I thyroid measurements. The lower detector could provide a good indication of the presence of surface contamination for adult, 15 y and 10 y phantoms. It is necessary to assume that surface contamination can be overlooked occasionally in the elevated background radiation level inAbstract: FASTSCAN (Canberra, Meriden, CT, USA), a standing-type whole-body counter with upper and lower NaI(Tl) detectors, has been mostly used to determine local residents' level of internal contamination with 134/137 Cs following the Fukushima Daiichi Nuclear Power Plant (FDNPP) disaster in 2011. In the present study, we performed Monte-Carlo simulations with age-specific mathematical human phantoms to investigate the counting efficiencies of the FASTSCAN counter for 131 I thyroid measurements. As a result, although the lower detector had low sensitivity for 131 I in the thyroids of the adult and 15 y phantoms as well as the 10 y phantom standing on a 30-cm-high stool, the response of this detector may be used as an indicator of surface contamination overlooked on a subject. The total counting efficiency investigated in this study was 0.017–0.018 (cps/Bq) among all age groups. Based on this sensitivity, the determination level for thyroid activity could be calculated to be ~300 Bq under the slightly elevated background radiation level observed after the FDNPP disaster. Highlights: The present study investigated the counting efficiencies of the whole-body counter called FASTSCAN for 131 I thyroid measurements. The lower detector could provide a good indication of the presence of surface contamination for adult, 15 y and 10 y phantoms. It is necessary to assume that surface contamination can be overlooked occasionally in the elevated background radiation level in challenging emergency situations. … (more)
- Is Part Of:
- Radiation measurements. Volume 135(2020:Apr.)
- Journal:
- Radiation measurements
- Issue:
- Volume 135(2020:Apr.)
- Issue Display:
- Volume 135 (2020)
- Year:
- 2020
- Volume:
- 135
- Issue Sort Value:
- 2020-0135-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07
- Subjects:
- Internal contamination -- 131I -- Thyroid measurement -- Whole-body counter
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2020.106335 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13573.xml