Development of postal dosimetry service using an alanine dosimeter in Japan. (July 2020)
- Record Type:
- Journal Article
- Title:
- Development of postal dosimetry service using an alanine dosimeter in Japan. (July 2020)
- Main Title:
- Development of postal dosimetry service using an alanine dosimeter in Japan
- Authors:
- Yamaguchi, Hidetoshi
Shimizu, Morihito
Morishita, Yuichiro
Okudaira, Kuniyasu
Oguchi, Hiroshi - Abstract:
- Abstract: The relative response of an alanine dosimeter to electron beams was evaluated using Co-60 gamma rays as a reference to establish an output dose-evaluation service. Alanine dosimeters were irradiated with 16-MeV electron beams and Co-60 gamma rays. For electron-beam irradiation, to ensure minimum dose gradient in alanine pellets, a thin holder with a different arrangement and material from a holder used in Co-60 gamma irradiation was employed. Monte Carlo simulations were conducted for electron beams from 12 MeV to 18 MeV to calculate the relative response and compare them with the experimental results. A correction factor for the acrylic holder was also calculated. The experimental relative response was 0.990. The experimental value agreed with the relative responses obtained by Monte Carlo calculations. The calculations with the electron beams of different energies showed that the response of the alanine dosimeter did not depend on the energy of the electron beams. The correction factor of the acrylic holder was approximately 1.004 for any incident energy. The dose of high-energy electron beams by the alanine dosimeter can be measured more easily using the relative response rather than the direct dose measurement from a calibration curve of electron beams. Highlights: Output dose-evaluation technique using an alanine dosimeter was developed. A relative response of alanine dosimeters to high-energy electron beams was 0.990. Dose measurement of electron beams can beAbstract: The relative response of an alanine dosimeter to electron beams was evaluated using Co-60 gamma rays as a reference to establish an output dose-evaluation service. Alanine dosimeters were irradiated with 16-MeV electron beams and Co-60 gamma rays. For electron-beam irradiation, to ensure minimum dose gradient in alanine pellets, a thin holder with a different arrangement and material from a holder used in Co-60 gamma irradiation was employed. Monte Carlo simulations were conducted for electron beams from 12 MeV to 18 MeV to calculate the relative response and compare them with the experimental results. A correction factor for the acrylic holder was also calculated. The experimental relative response was 0.990. The experimental value agreed with the relative responses obtained by Monte Carlo calculations. The calculations with the electron beams of different energies showed that the response of the alanine dosimeter did not depend on the energy of the electron beams. The correction factor of the acrylic holder was approximately 1.004 for any incident energy. The dose of high-energy electron beams by the alanine dosimeter can be measured more easily using the relative response rather than the direct dose measurement from a calibration curve of electron beams. Highlights: Output dose-evaluation technique using an alanine dosimeter was developed. A relative response of alanine dosimeters to high-energy electron beams was 0.990. Dose measurement of electron beams can be performed using relative response and a calibration curve for Co-60 gamma rays. … (more)
- Is Part Of:
- Radiation measurements. Volume 135(2020:Apr.)
- Journal:
- Radiation measurements
- Issue:
- Volume 135(2020:Apr.)
- Issue Display:
- Volume 135 (2020)
- Year:
- 2020
- Volume:
- 135
- Issue Sort Value:
- 2020-0135-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07
- Subjects:
- Alanine dosimeter -- High-energy electron beams -- Co-60 gamma ray -- Relative response -- Calibration curve
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2020.106339 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13573.xml