Validation of the suppression ratio from a simplified EEG montage during targeted temperature management after cardiac arrest. (August 2020)
- Record Type:
- Journal Article
- Title:
- Validation of the suppression ratio from a simplified EEG montage during targeted temperature management after cardiac arrest. (August 2020)
- Main Title:
- Validation of the suppression ratio from a simplified EEG montage during targeted temperature management after cardiac arrest
- Authors:
- Riker, Richard R.
Craig, Alexa
Eubank, Louis
May, Teresa
Seder, David B. - Abstract:
- Abstract: Aim: The Suppression Ratio (SR) estimates the percent of the electroencephalography (EEG) epoch with very low voltage, and is associated with neurological outcome after cardiac arrest. We aimed to compare the SR generated by two monitoring devices and determine the association between SR and patterns on amplitude integrated EEG (aEEG) and full conventional EEG (cEEG). Methods: Consecutive adult patients treated with TTM after cardiac arrest were enrolled. We compared the SR from the Medtronic Vista monitor (MSR) to the SR generated from the full montage cEEG with Persyst Magic-Marker software (PSR). A blinded neurologist, board certified in epilepsy, scored the 4-channel aEEG pattern and the cEEG background using standardized terminology. Values for SR were compared to aEEG and cEEG categories using Kruskal–Wallis ANOVA, and to each other using Altman-Bland methodology. Results: 23 adults treated with TTM had a mean core temperature of 33.8 °C at the time of SR and EEG background analysis. The MSR was 0% during continuous cEEG background, 23% when cEEG was discontinuous, and 64% during cEEG burst suppression ( p = 0.01). The MSR was 0% during aEEG continuous patterns, 34% during aEEG burst suppression, and 46% during flat aEEG ( p < 0.001). The MSR and PSR were highly correlated (0.88, p < 0.0001), with minimal bias (0.3%) and excellent 95% limits of agreement (−2.9 to 2.4%). Conclusion: The Suppression Ratio from the Medtronic Vista monitor is highly correlatedAbstract: Aim: The Suppression Ratio (SR) estimates the percent of the electroencephalography (EEG) epoch with very low voltage, and is associated with neurological outcome after cardiac arrest. We aimed to compare the SR generated by two monitoring devices and determine the association between SR and patterns on amplitude integrated EEG (aEEG) and full conventional EEG (cEEG). Methods: Consecutive adult patients treated with TTM after cardiac arrest were enrolled. We compared the SR from the Medtronic Vista monitor (MSR) to the SR generated from the full montage cEEG with Persyst Magic-Marker software (PSR). A blinded neurologist, board certified in epilepsy, scored the 4-channel aEEG pattern and the cEEG background using standardized terminology. Values for SR were compared to aEEG and cEEG categories using Kruskal–Wallis ANOVA, and to each other using Altman-Bland methodology. Results: 23 adults treated with TTM had a mean core temperature of 33.8 °C at the time of SR and EEG background analysis. The MSR was 0% during continuous cEEG background, 23% when cEEG was discontinuous, and 64% during cEEG burst suppression ( p = 0.01). The MSR was 0% during aEEG continuous patterns, 34% during aEEG burst suppression, and 46% during flat aEEG ( p < 0.001). The MSR and PSR were highly correlated (0.88, p < 0.0001), with minimal bias (0.3%) and excellent 95% limits of agreement (−2.9 to 2.4%). Conclusion: The Suppression Ratio from the Medtronic Vista monitor is highly correlated with the full montage SR from Persyst software. The MSR values are valid, changing with different aEEG patterns and cEEG background categories. … (more)
- Is Part Of:
- Resuscitation. Volume 153(2020)
- Journal:
- Resuscitation
- Issue:
- Volume 153(2020)
- Issue Display:
- Volume 153, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 153
- Issue:
- 2020
- Issue Sort Value:
- 2020-0153-2020-0000
- Page Start:
- 1
- Page End:
- 5
- Publication Date:
- 2020-08
- Subjects:
- Electroencephalogram -- Suppression -- Cardiac arrest -- Hypoxic–ischemic encephalopathy -- Validity -- Agreement
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2020.05.014 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13571.xml