Comparison and evaluation of Abbott chemiluminescent microparticle immunoassay and ChIVD light‐initiated chemiluminescent assay in the detection of Treponema pallidum antibody. Issue 7 (4th March 2020)
- Record Type:
- Journal Article
- Title:
- Comparison and evaluation of Abbott chemiluminescent microparticle immunoassay and ChIVD light‐initiated chemiluminescent assay in the detection of Treponema pallidum antibody. Issue 7 (4th March 2020)
- Main Title:
- Comparison and evaluation of Abbott chemiluminescent microparticle immunoassay and ChIVD light‐initiated chemiluminescent assay in the detection of Treponema pallidum antibody
- Authors:
- Chen, Xiaohui
Yang, Ruifeng
Liang, Yongming
Yuan, Teng
Zhou, Jiansuo
Wang, Tiancheng
Cui, Liyan - Abstract:
- Abstract: Background: Laboratory tests play an important role in the diagnosis of syphilis. This study aimed to compare and assess the performance of the Abbott chemiluminescent microparticle immunoassay (CMIA) and the ChIVD light‐initiated chemiluminescent assay (LICA) in the detection of Treponema pallidum ( TP ) antibody. Methods: A total of 10 498 serum samples were detected with two assays, and the Treponema pallidum particle agglutination assay (TPPA) and recombinant immunoblot assay (RIBA) methods were used for confirmation. The sensitivity, specificity, positive predictive value, and negative predictive value of the Abbott CMIA and ChIVD LICA were calculated. The coincidence rate between two assays was also evaluated. The causes of false positive and false negative of two assays were studied. Results: For the Abbott CMIA and ChIVD LICA, the sensitivity was 94.44% and 98.15%, the specificity was 99.89% and 99.81%, the positive predictive value was 93.29% and 88.83%, and the negative predictive value was 99.91% and 99.97%, respectively. The coincidence rate between Abbott CMIA and ChIVD LICA was 99.26%, and κ value was .790. The disease of infertility, hypertensive disease, liver disease, and cancer were the common causes of false positive in both assays, while infertility was also the main reason lead to false negative. Conclusion: Our results demonstrated that the Abbott CMIA and ChIVD LICA generally had high sensitivity and specificity and therefore may be suitableAbstract: Background: Laboratory tests play an important role in the diagnosis of syphilis. This study aimed to compare and assess the performance of the Abbott chemiluminescent microparticle immunoassay (CMIA) and the ChIVD light‐initiated chemiluminescent assay (LICA) in the detection of Treponema pallidum ( TP ) antibody. Methods: A total of 10 498 serum samples were detected with two assays, and the Treponema pallidum particle agglutination assay (TPPA) and recombinant immunoblot assay (RIBA) methods were used for confirmation. The sensitivity, specificity, positive predictive value, and negative predictive value of the Abbott CMIA and ChIVD LICA were calculated. The coincidence rate between two assays was also evaluated. The causes of false positive and false negative of two assays were studied. Results: For the Abbott CMIA and ChIVD LICA, the sensitivity was 94.44% and 98.15%, the specificity was 99.89% and 99.81%, the positive predictive value was 93.29% and 88.83%, and the negative predictive value was 99.91% and 99.97%, respectively. The coincidence rate between Abbott CMIA and ChIVD LICA was 99.26%, and κ value was .790. The disease of infertility, hypertensive disease, liver disease, and cancer were the common causes of false positive in both assays, while infertility was also the main reason lead to false negative. Conclusion: Our results demonstrated that the Abbott CMIA and ChIVD LICA generally had high sensitivity and specificity and therefore may be suitable for the detection of TP antibody and screening for syphilis. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 34:Issue 7(2020)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 34:Issue 7(2020)
- Issue Display:
- Volume 34, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 7
- Issue Sort Value:
- 2020-0034-0007-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-03-04
- Subjects:
- Abbott chemiluminescent microparticle immunoassay -- ChIVD light‐initiated chemiluminescent assay -- recombinant immunoblot assay -- syphilis -- Treponema pallidum -- Treponema pallidum particle agglutination
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.23275 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13552.xml