Reliability of manometry for assessing pelvic floor muscle function in healthy men. Issue 5 (27th April 2020)
- Record Type:
- Journal Article
- Title:
- Reliability of manometry for assessing pelvic floor muscle function in healthy men. Issue 5 (27th April 2020)
- Main Title:
- Reliability of manometry for assessing pelvic floor muscle function in healthy men
- Authors:
- Ouchi, Mifuka
Kitta, Takeya
Takahashi, Yui
Chiba, Hiroki
Higuchi, Madoka
Togo, Mio
Shinohara, Nobuo - Abstract:
- Abstract: Objectives: To the best of our knowledge, no study has examined the reliability of assessment methods for male pelvic floor muscle (PFM) function. Therefore, this study aimed to clarify the reliability of manometry with an anal sensor (Peritron cat 9300A) to assess PFM function in healthy men. Methods: Healthy male subjects (n = 21) without urinary leakage underwent testing to assess PFM function, and intra‐ and interrater reliability tests among examiners were performed. The PFM function included maximal anorectal squeeze pressure, endurance, mean anorectal squeeze pressure, gradient, and area under the curve during PFM voluntary contraction. Results: Participants had a median age of 38 years (range 26‐51), and a mean BMI of 23.2 ± 2.0 kg/m 2 . Satisfactory intra‐ and interrater reliability scores were found for resting pressure, anorectal squeeze pressure, and endurance. The intra‐rater reliability of resting pressure, anorectal squeeze pressure, and endurance were 0.71, 0.89, and 0.75 for examiner 1 and 0.72, 0.89, and 0.87 for examiner 2. The interrater reliability for resting pressure, anorectal squeeze pressure, and endurance were 0.58, 0.93, and 0.61, respectively. Conclusions: This is the first prospective study showing the favorable intra‐ and interrater reliability of manometry for PFM function in healthy men. Our findings demonstrated that manometry can provide both reliable and reproducible data regarding PFM function in continent men, suggestingAbstract: Objectives: To the best of our knowledge, no study has examined the reliability of assessment methods for male pelvic floor muscle (PFM) function. Therefore, this study aimed to clarify the reliability of manometry with an anal sensor (Peritron cat 9300A) to assess PFM function in healthy men. Methods: Healthy male subjects (n = 21) without urinary leakage underwent testing to assess PFM function, and intra‐ and interrater reliability tests among examiners were performed. The PFM function included maximal anorectal squeeze pressure, endurance, mean anorectal squeeze pressure, gradient, and area under the curve during PFM voluntary contraction. Results: Participants had a median age of 38 years (range 26‐51), and a mean BMI of 23.2 ± 2.0 kg/m 2 . Satisfactory intra‐ and interrater reliability scores were found for resting pressure, anorectal squeeze pressure, and endurance. The intra‐rater reliability of resting pressure, anorectal squeeze pressure, and endurance were 0.71, 0.89, and 0.75 for examiner 1 and 0.72, 0.89, and 0.87 for examiner 2. The interrater reliability for resting pressure, anorectal squeeze pressure, and endurance were 0.58, 0.93, and 0.61, respectively. Conclusions: This is the first prospective study showing the favorable intra‐ and interrater reliability of manometry for PFM function in healthy men. Our findings demonstrated that manometry can provide both reliable and reproducible data regarding PFM function in continent men, suggesting Peritron cat 9300A can be used to evaluate the PFM function in men. … (more)
- Is Part Of:
- Neurourology and urodynamics. Volume 39:Issue 5(2020:Jun.)
- Journal:
- Neurourology and urodynamics
- Issue:
- Volume 39:Issue 5(2020:Jun.)
- Issue Display:
- Volume 39, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 39
- Issue:
- 5
- Issue Sort Value:
- 2020-0039-0005-0000
- Page Start:
- 1464
- Page End:
- 1471
- Publication Date:
- 2020-04-27
- Subjects:
- healthy men -- intra‐ and interrater reliability -- pelvic floor muscle function
Urinary organs -- Periodicals
Urodynamics -- Periodicals
Urology -- Periodicals
616.6 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1520-6777 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/nau.24374 ↗
- Languages:
- English
- ISSNs:
- 0733-2467
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.589000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13556.xml