Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia. Issue 127 (June 2020)
- Record Type:
- Journal Article
- Title:
- Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia. Issue 127 (June 2020)
- Main Title:
- Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia
- Authors:
- Zalokar, Nika
Žager Marciuš, Valerija
Mekiš, Nejc - Abstract:
- Highlights: Radiotherapy CT localization doses are not insignificant. RT CT simulation doses are generally higher than diagnostic CT. In our study the DLP values were on average higher for 70 % in comparison to diagnostic CT. CT simulation DRLs in RT are established for radiation protection of patients. Abstract: Purpose: To propose national diagnostic reference levels (DRLs) for radiotherapy (RT) computed tomography (CT) localization purposes, compare both CT units used in the largest RT department in the country and to compare gathered results with other published DRLs in order to discover any need of optimization. Methods: In total, 1631 patient data (time spend of 4 months) regarding sex, examination type, total dose-length product (DLP) and CTDIvol was collated on two CT units. Those simulation procedures account for more than 80 % of all simulation procedures performed nationwide. Then, total DLP and CTDIvol was calculated and mean, median and 3 rd quartile for both units together were presented to determine national DRLs for simulation procedures. The same data was later compared between both units to discover any potential need for optimization. Results: 3 rd quartile values of DLP for abdomen, breast, chest, head, head and neck, pelvis and spine were 1116.2, 606.6, 832.4, 1942.4, 969.2, 677.1 and 1042.4 mGy∙cm, respectively. 3 rd quartile CTDIvol values for the same sequence of procedures were 18.7, 13.3, 19.2, 76.9, 22.6, 17.9 and 22.2 mGy, respectively. Among theHighlights: Radiotherapy CT localization doses are not insignificant. RT CT simulation doses are generally higher than diagnostic CT. In our study the DLP values were on average higher for 70 % in comparison to diagnostic CT. CT simulation DRLs in RT are established for radiation protection of patients. Abstract: Purpose: To propose national diagnostic reference levels (DRLs) for radiotherapy (RT) computed tomography (CT) localization purposes, compare both CT units used in the largest RT department in the country and to compare gathered results with other published DRLs in order to discover any need of optimization. Methods: In total, 1631 patient data (time spend of 4 months) regarding sex, examination type, total dose-length product (DLP) and CTDIvol was collated on two CT units. Those simulation procedures account for more than 80 % of all simulation procedures performed nationwide. Then, total DLP and CTDIvol was calculated and mean, median and 3 rd quartile for both units together were presented to determine national DRLs for simulation procedures. The same data was later compared between both units to discover any potential need for optimization. Results: 3 rd quartile values of DLP for abdomen, breast, chest, head, head and neck, pelvis and spine were 1116.2, 606.6, 832.4, 1942.4, 969.2, 677.1 and 1042.4 mGy∙cm, respectively. 3 rd quartile CTDIvol values for the same sequence of procedures were 18.7, 13.3, 19.2, 76.9, 22.6, 17.9 and 22.2 mGy, respectively. Among the two units, the mentioned dose values were on average significantly higher on one CT unit than on the other unit. Conclusions: When comparing collected dose values with other studies, RT CT DRLs showed that radiation doses from our institution were similar or even lower. Some variations were found between both CT units in certain protocols, so exposure parameters should be reviewed and optimized. … (more)
- Is Part Of:
- European journal of radiology. Issue 127(2020)
- Journal:
- European journal of radiology
- Issue:
- Issue 127(2020)
- Issue Display:
- Volume 127, Issue 127 (2020)
- Year:
- 2020
- Volume:
- 127
- Issue:
- 127
- Issue Sort Value:
- 2020-0127-0127-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06
- Subjects:
- Computed tomography -- DRL -- Radiotherapy simulation -- CT
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2020.108979 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13546.xml