Experimental investigation on the vortex-induced vibration of the vertical riser fitted with the water jetting active vibration suppression device. (1st July 2020)
- Record Type:
- Journal Article
- Title:
- Experimental investigation on the vortex-induced vibration of the vertical riser fitted with the water jetting active vibration suppression device. (1st July 2020)
- Main Title:
- Experimental investigation on the vortex-induced vibration of the vertical riser fitted with the water jetting active vibration suppression device
- Authors:
- Liu, Yu
Li, Peng
Wang, Yu
Guo, Haiyan
Zhang, Xiantang - Abstract:
- Highlights: A water jetting active vibration suppression device is proposed, and the optimal suppression efficiency can reach 92%. Study on the vibration suppression efficiency of the water jetting active vibration suppression device on the vortex-induced vibration of the riser and the influence on the dynamic response of the riser. Not the smaller the test spacing is, the better the vibration suppression effect is, but there is a sensitive region during test spacing of the water jetting active vibration suppression device. As the reduced velocity increases, the test spacing of the water jetting active vibration suppression device is changed from 7.5 D to 10.0 D, the efficiency of vibration suppression is polarized and obvious "transition region" appears. Abstract: In this paper, a type of water jetting active vibration suppression device was designed. Experimental studies were carried out to investigate the dynamic responses and the vortex-induced vibration suppression effect for a vertical riser with the water jetting active vibration suppression device in a wave-current flume. By varying the multi-stage outflow velocities and the test spacings, the characteristic parameters such as dominant frequency, dimensionless displacement and mode of the riser after vibration suppression under different test spacings of the water jetting active vibration suppression device were analyzed. The results show that the vibration suppression device effectively suppresses the VIV of theHighlights: A water jetting active vibration suppression device is proposed, and the optimal suppression efficiency can reach 92%. Study on the vibration suppression efficiency of the water jetting active vibration suppression device on the vortex-induced vibration of the riser and the influence on the dynamic response of the riser. Not the smaller the test spacing is, the better the vibration suppression effect is, but there is a sensitive region during test spacing of the water jetting active vibration suppression device. As the reduced velocity increases, the test spacing of the water jetting active vibration suppression device is changed from 7.5 D to 10.0 D, the efficiency of vibration suppression is polarized and obvious "transition region" appears. Abstract: In this paper, a type of water jetting active vibration suppression device was designed. Experimental studies were carried out to investigate the dynamic responses and the vortex-induced vibration suppression effect for a vertical riser with the water jetting active vibration suppression device in a wave-current flume. By varying the multi-stage outflow velocities and the test spacings, the characteristic parameters such as dominant frequency, dimensionless displacement and mode of the riser after vibration suppression under different test spacings of the water jetting active vibration suppression device were analyzed. The results show that the vibration suppression device effectively suppresses the VIV of the riser under different test spacings. The coupling relationship between test spacing and reduced velocity is the key factor for the optimal vibration suppression effect of the active vibration suppression device. The amplitude of the displacement after suppression is significantly reduced compared with that before suppression, and the best suppression efficiency can reach 92%. At the same time, it is found that not the smaller the test spacing is, the better the vibration suppression effect is, but there is a sensitive region during test spacing. As the reduced velocity increases, the test spacing of the water jetting active vibration suppression device is changed from 7.5 D to 10.0 D, the efficiency of vibration suppression is polarized and obvious "transition region" appears. Graphical abstract: Image, graphical abstract … (more)
- Is Part Of:
- International journal of mechanical sciences. Volume 177(2020)
- Journal:
- International journal of mechanical sciences
- Issue:
- Volume 177(2020)
- Issue Display:
- Volume 177, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 177
- Issue:
- 2020
- Issue Sort Value:
- 2020-0177-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07-01
- Subjects:
- Vortex-induced vibration -- Vertical riser -- Active vibration suppression -- Water jetting type -- Test spacing
Mechanical engineering -- Periodicals
Génie mécanique -- Périodiques
Mechanical engineering
Maschinenbau
Mechanik
Zeitschrift
Periodicals
621.05 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00207403 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijmecsci.2020.105600 ↗
- Languages:
- English
- ISSNs:
- 0020-7403
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.344000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13542.xml