Two‐year follow‐up of a randomized multicenter study comparing a drug‐coated balloon with a drug‐eluting stent in native small coronary vessels: The RESTORE Small Vessel Disease China trial. (13th January 2020)
- Record Type:
- Journal Article
- Title:
- Two‐year follow‐up of a randomized multicenter study comparing a drug‐coated balloon with a drug‐eluting stent in native small coronary vessels: The RESTORE Small Vessel Disease China trial. (13th January 2020)
- Main Title:
- Two‐year follow‐up of a randomized multicenter study comparing a drug‐coated balloon with a drug‐eluting stent in native small coronary vessels: The RESTORE Small Vessel Disease China trial
- Authors:
- Tian, Jian
Tang, Yi‐da
Qiao, Shubin
Su, Xi
Chen, Yundai
Jin, Zening
Chen, Hui
Xu, Biao
Kong, Xiangqing
Pang, Wenyue
Liu, Yong
Yu, Zaixin
Li, Xue
Li, Hui
Zhao, Yanyan
Wang, Yang
Li, Wei
Guan, Changdong
Gao, Runlin
Xu, Bo - Other Names:
- Gao Runlin guestEditor.
Xu Bo guestEditor. - Abstract:
- Abstract: Objectives: To report the clinical outcomes of the RESTORE drug‐coated balloon (DCB; Cardionovum, Bonn, Germany) for treatment of de novo small vessel disease (SVD) beyond 1 year. Background: Previous reports have demonstrated the noninferiority of the RESTORE DCB to the RESOLUTE Integrity drug‐eluting stent (DES; Medtronic, Minneapolis, Minnesota) in terms of 9‐month in‐segment percent diameter stenosis. Methods: In the prospective, multicenter, noninferiority RESTORE SVD China trial, 230 patients with visually‐estimated reference vessel diameter (RVD) ≥2.25 and ≤2.75 mm were randomized to DCB or DES in a 1:1 ratio stratified by diabetes and number of lesions treated. Furthermore, 32 patients with RVD ≥2.00 and <2.25 mm were enrolled in a nested very small vessel (VSV) registry. Clinical follow‐up were performed at 2 years to evaluate target lesion failure (TLF) in both groups and the VSV cohort. Results: Overall, 256 (97.7%) patients (115 and 109 in the DCB and DES groups, respectively, and 32 in the VSV cohort) completed 2 years of follow‐up. There was no significant difference in TLF between the DCB and DES groups (5.2 vs. 3.7%, p = .75). Target lesion revascularization was acceptable at 1 month, 1 year, and 2 years, and did not differ significantly with DCB from that in the DES group (0.9 vs. 0%, p = 1.0, 4.4 vs. 2.6%, p = .72, 5.2 vs. 2.8%, p = .50, respectively). Conclusions: Compared to the second‐generation DES, the RESTORE DCB did not increase the risk ofAbstract: Objectives: To report the clinical outcomes of the RESTORE drug‐coated balloon (DCB; Cardionovum, Bonn, Germany) for treatment of de novo small vessel disease (SVD) beyond 1 year. Background: Previous reports have demonstrated the noninferiority of the RESTORE DCB to the RESOLUTE Integrity drug‐eluting stent (DES; Medtronic, Minneapolis, Minnesota) in terms of 9‐month in‐segment percent diameter stenosis. Methods: In the prospective, multicenter, noninferiority RESTORE SVD China trial, 230 patients with visually‐estimated reference vessel diameter (RVD) ≥2.25 and ≤2.75 mm were randomized to DCB or DES in a 1:1 ratio stratified by diabetes and number of lesions treated. Furthermore, 32 patients with RVD ≥2.00 and <2.25 mm were enrolled in a nested very small vessel (VSV) registry. Clinical follow‐up were performed at 2 years to evaluate target lesion failure (TLF) in both groups and the VSV cohort. Results: Overall, 256 (97.7%) patients (115 and 109 in the DCB and DES groups, respectively, and 32 in the VSV cohort) completed 2 years of follow‐up. There was no significant difference in TLF between the DCB and DES groups (5.2 vs. 3.7%, p = .75). Target lesion revascularization was acceptable at 1 month, 1 year, and 2 years, and did not differ significantly with DCB from that in the DES group (0.9 vs. 0%, p = 1.0, 4.4 vs. 2.6%, p = .72, 5.2 vs. 2.8%, p = .50, respectively). Conclusions: Compared to the second‐generation DES, the RESTORE DCB did not increase the risk of clinical outcomes. Late catch‐up phenomen requiring revascularization was not significant in this study. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 95(2020)Supplement 1
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 95(2020)Supplement 1
- Issue Display:
- Volume 95, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 95
- Issue:
- 1
- Issue Sort Value:
- 2020-0095-0001-0000
- Page Start:
- 587
- Page End:
- 597
- Publication Date:
- 2020-01-13
- Subjects:
- coronary artery disease -- percutaneous coronary intervention -- angioplasty, balloon, coronary -- stents -- follow‐up studies
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.28705 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13538.xml