Comparison of four inflation techniques on endotracheal tube cuff pressure using a feline airway simulator. Issue 7 (July 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of four inflation techniques on endotracheal tube cuff pressure using a feline airway simulator. Issue 7 (July 2020)
- Main Title:
- Comparison of four inflation techniques on endotracheal tube cuff pressure using a feline airway simulator
- Authors:
- White, Donna M
Makara, Mariano
Martinez-Taboada, Fernando - Abstract:
- Objectives: The aim of this study was to compare four inflation techniques on endotracheal tube cuff (ETC) pressure using a feline airway simulator. Methods: Ten participants used four different endotracheal cuff inflation techniques to inflate the cuff of a low-pressure, high-volume endotracheal tube within a feline airway simulator. The simulator replicated an average-sized feline trachea, intubated with a 4.5 mm endotracheal tube, connected to a circle breathing system and pressure-controlled ventilation with oxygen and medical air. Participants inflated the ETC: by pilot balloon palpation (P); by instilling the minimum occlusive volume (MOV) required for loss of airway leaks during mechanical ventilation; until a passive release of pressure with use of a loss-of-resistance syringe (LOR); and with use of a syringe with a digital pressure reader (D) specifically designed for endotracheal cuff inflation. Intracuff pressure was measured by a manometer obscured to participants. The ideal pressure was considered to be between 20 and 30 cmH2 O. Data were analysed by Shapiro–Wilk, Kruskal–Wallis and χ 2 tests, as appropriate. Results: Participants were eight veterinarians and two veterinary nurses with additional training in anaesthesia. Measured median intracuff pressures for P, MOV, LOR and D, respectively, were 25 cmH2 O (range 4–74 cmH2 O), 41 cmH2 O (range 4–70 cmH2 O), 31 cmH2 O (range 18–64 cmH2 O) and 22 cmH2 O (range 20–30 cmH2 O). D performed significantly better ( PObjectives: The aim of this study was to compare four inflation techniques on endotracheal tube cuff (ETC) pressure using a feline airway simulator. Methods: Ten participants used four different endotracheal cuff inflation techniques to inflate the cuff of a low-pressure, high-volume endotracheal tube within a feline airway simulator. The simulator replicated an average-sized feline trachea, intubated with a 4.5 mm endotracheal tube, connected to a circle breathing system and pressure-controlled ventilation with oxygen and medical air. Participants inflated the ETC: by pilot balloon palpation (P); by instilling the minimum occlusive volume (MOV) required for loss of airway leaks during mechanical ventilation; until a passive release of pressure with use of a loss-of-resistance syringe (LOR); and with use of a syringe with a digital pressure reader (D) specifically designed for endotracheal cuff inflation. Intracuff pressure was measured by a manometer obscured to participants. The ideal pressure was considered to be between 20 and 30 cmH2 O. Data were analysed by Shapiro–Wilk, Kruskal–Wallis and χ 2 tests, as appropriate. Results: Participants were eight veterinarians and two veterinary nurses with additional training in anaesthesia. Measured median intracuff pressures for P, MOV, LOR and D, respectively, were 25 cmH2 O (range 4–74 cmH2 O), 41 cmH2 O (range 4–70 cmH2 O), 31 cmH2 O (range 18–64 cmH2 O) and 22 cmH2 O (range 20–30 cmH2 O). D performed significantly better ( P <0.001) than all other techniques, with no difference between the other techniques. Conclusions and relevance: Use of D for cuff inflation achieved optimal cuff pressures. There may be high operator-dependent variability in the cuff pressures achieved with the use of P, MOV or LOR inflation techniques. As such, a cuff manometer is recommended when using any of these techniques. … (more)
- Is Part Of:
- Journal of feline medicine and surgery. Volume 22:Issue 7(2020)
- Journal:
- Journal of feline medicine and surgery
- Issue:
- Volume 22:Issue 7(2020)
- Issue Display:
- Volume 22, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 7
- Issue Sort Value:
- 2020-0022-0007-0000
- Page Start:
- 641
- Page End:
- 647
- Publication Date:
- 2020-07
- Subjects:
- Anaesthesia -- endotracheal intubation -- intracuff pressure -- simulator
Cats -- Diseases -- Periodicals
Cats -- Surgery -- Periodicals
636.8089 - Journal URLs:
- http://jfm.sagepub.com/ ↗
http://www.sciencedirect.com/science/journal/1098612X ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1098612X19871701 ↗
- Languages:
- English
- ISSNs:
- 1098-612X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4983.933000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13523.xml