Atomic Absorption Spectrometry Methods to Access the Metal Solubility of Aerosols in Artificial Lung Fluid. Issue 8 (August 2020)
- Record Type:
- Journal Article
- Title:
- Atomic Absorption Spectrometry Methods to Access the Metal Solubility of Aerosols in Artificial Lung Fluid. Issue 8 (August 2020)
- Main Title:
- Atomic Absorption Spectrometry Methods to Access the Metal Solubility of Aerosols in Artificial Lung Fluid
- Authors:
- Polezer, Gabriela
Godoi, Ricardo H. M.
Potgieter-Vermaak, Sanja
de Souza, Rodrigo A. F.
Andreoli, Rita V.
Yamamoto, Carlos I.
Oliveira, Andrea - Abstract:
- Recent studies to quantify the health risks that fine particulate matter with an aerodynamic less than 2.5 µm (PM2.5 ) pose use in vitro approaches. One of these approaches is to incubate PM2.5 in artificial lysosomal fluid for a given period at body temperature. These body fluids used have a high ionic strength and as such can be challenging samples to analyze with atomic spectroscopy techniques. As PM2.5 is a primary health hazard because it is tiny enough to penetrate deep into the lungs and could, in addition, dissolve in the lung fluid it is important to quantify elements of toxic and/or carcinogenic concerns, reliably and accurately. Sophisticated instrumentation and expensive pre-treatment of challenging samples are not always available, especially in developing countries. To evaluate the applicability of graphite furnace atomic absorption spectrometry (GFAAS) without Zeeman correction capability to detect trace quantities of heavy metals leached from PM2.5 on to artificial lung fluid, univariate and multivariate approaches have been used for optimization purposes. The limits of quantification, LOQ, obtained by the optimized method were: 2 µg L −1 (Cu), 3 µg L −1 (Cr), 1 µg L −1 (Mn), and 10 µg L −1 (Pb). The addition/recovery experiments had a mean accuracy of: (Cu) 99 ± 7%; 110 ± 8% (Cr); 95 ± 9% (Mn), and 96 ± 11% (Pb). The average soluble fractions of PM2.5 incubated in artificial lysosomal fluid (ALF) for 1 h were: 1.2 ± 0.01 ng m −3 Cu, 0.4 ± 0.01 ng m −3 Cr,Recent studies to quantify the health risks that fine particulate matter with an aerodynamic less than 2.5 µm (PM2.5 ) pose use in vitro approaches. One of these approaches is to incubate PM2.5 in artificial lysosomal fluid for a given period at body temperature. These body fluids used have a high ionic strength and as such can be challenging samples to analyze with atomic spectroscopy techniques. As PM2.5 is a primary health hazard because it is tiny enough to penetrate deep into the lungs and could, in addition, dissolve in the lung fluid it is important to quantify elements of toxic and/or carcinogenic concerns, reliably and accurately. Sophisticated instrumentation and expensive pre-treatment of challenging samples are not always available, especially in developing countries. To evaluate the applicability of graphite furnace atomic absorption spectrometry (GFAAS) without Zeeman correction capability to detect trace quantities of heavy metals leached from PM2.5 on to artificial lung fluid, univariate and multivariate approaches have been used for optimization purposes. The limits of quantification, LOQ, obtained by the optimized method were: 2 µg L −1 (Cu), 3 µg L −1 (Cr), 1 µg L −1 (Mn), and 10 µg L −1 (Pb). The addition/recovery experiments had a mean accuracy of: (Cu) 99 ± 7%; 110 ± 8% (Cr); 95 ± 9% (Mn), and 96 ± 11% (Pb). The average soluble fractions of PM2.5 incubated in artificial lysosomal fluid (ALF) for 1 h were: 1.2 ± 0.01 ng m −3 Cu, 0.4 ± 0.01 ng m −3 Cr, 0.6 ± 0.01 ng m −3 Mn, and 4.8 ± 0.03 ng m −3 Pb. Using historical elemental averages of PM2.5 in Curitiba (Cu 3.3 ng m −3, Cr 2.1 ng m −3, Mn 6.1 ng m −3, Pb 21 ng m −3 ), the percentage bioaccessibility were determined to be Cu 38%, Cr 20%, Mn 10%, and Pb 23%. The elemental values of the atmospheric soluble fraction of Cu, Cr, and Mn were below the inhalation risk concentrations. However, for Pb, the atmospheric soluble fraction exceeded the inhalation unit risk of 0.012 ng m −3 . This robust and straightforward GF AAS method is pivotal for low and middle-income countries were most air pollution adverse effects occur and established lower-cost technologies are likely unavailable. … (more)
- Is Part Of:
- Applied spectroscopy. Volume 74:Issue 8(2020)
- Journal:
- Applied spectroscopy
- Issue:
- Volume 74:Issue 8(2020)
- Issue Display:
- Volume 74, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 74
- Issue:
- 8
- Issue Sort Value:
- 2020-0074-0008-0000
- Page Start:
- 932
- Page End:
- 939
- Publication Date:
- 2020-08
- Subjects:
- Bioaccessibility -- PM2.5 -- artificial lysosomal fluid -- inorganic elements -- graphite furnace atomic absorption spectrometry -- GFAAS
Spectrum analysis -- Periodicals
543.505 - Journal URLs:
- http://asp.sagepub.com/ ↗
http://www.ingentaconnect.com/content/sas/sas ↗
http://www.uk.sagepub.com/home.nav ↗
http://firstsearch.oclc.org/journal=0003-7028;screen=info;ECOIP ↗ - DOI:
- 10.1177/0003702820906422 ↗
- Languages:
- English
- ISSNs:
- 0003-7028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13530.xml