Fabrication and properties of the thickness mode ultrasonic transducer based on 0.15Pb(Mg1/3Nb2/3)O3-0.38PbHfO3-0.47PbTiO3 piezoelectric ceramics. Issue 8 (1st June 2020)
- Record Type:
- Journal Article
- Title:
- Fabrication and properties of the thickness mode ultrasonic transducer based on 0.15Pb(Mg1/3Nb2/3)O3-0.38PbHfO3-0.47PbTiO3 piezoelectric ceramics. Issue 8 (1st June 2020)
- Main Title:
- Fabrication and properties of the thickness mode ultrasonic transducer based on 0.15Pb(Mg1/3Nb2/3)O3-0.38PbHfO3-0.47PbTiO3 piezoelectric ceramics
- Authors:
- Wang, Jushan
Xiao, Junjie
Zhao, Xiangyong
Wang, Feifei
Tang, Yanxue
Zhang, Qiaozhen
Fang, Bijun
Zhu, Rongfeng
Yue, Qingwen
Liu, Dongxu
Deng, Ji - Abstract:
- Abstract: In this paper, the 0.15Pb(Mg1/3 Nb2/3 )O3 -0.38PbHfO3 -0.47PbTiO3 ternary piezoelectric ceramic fabricated by the partial oxalate method that exhibits superior electrical properties ( d 33 = 447 pC/N and k t = 56.9%) and excellent thermal stability of the piezoelectric properties below T C was studied. The newly discovered piezoelectric ceramic had a high Curie temperature ( T m = 297 °C), this feature was used to fabricate a novel single-element ultrasonic transducer whose center frequency was 2.15 MHz, with a −6 dB bandwidth of up to 79.07%, and a sensitivity that reached −31.75 dB. The result of the experiment agreed well with that of PiezoCAD software based on the KLM model. This transducer's outstanding thermal stability below T C can be widely used in non-destructive evaluation. At the same time, we measured the sound field distribution of the ultrasonic transducer. The focal length was measured approximately 47 mm. An obvious main lobe was clearly seen from the z–x scan. The power was measured as 17.98 mW; the beam width of –3dB was 3.5 × 3.6 mm; and the area was 9.83 mm 2 according to the FDA and IEC standards.
- Is Part Of:
- Ceramics international. Volume 46:Issue 8(2020)Part B
- Journal:
- Ceramics international
- Issue:
- Volume 46:Issue 8(2020)Part B
- Issue Display:
- Volume 46, Issue 8, Part 2 (2020)
- Year:
- 2020
- Volume:
- 46
- Issue:
- 8
- Part:
- 2
- Issue Sort Value:
- 2020-0046-0008-0002
- Page Start:
- 11913
- Page End:
- 11920
- Publication Date:
- 2020-06-01
- Subjects:
- The PMN-PH-PT ceramics -- High curie temperature -- Ultrasonic transducer -- Non-destructive evaluation
Ceramics -- Periodicals
Céramique industrielle -- Périodiques
Ceramics
Periodicals
Electronic journals
666 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02728842 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ceramint.2020.01.228 ↗
- Languages:
- English
- ISSNs:
- 0272-8842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3119.015000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13533.xml