The effect of cardiac output on the pharmacokinetics and pharmacodynamics of propofol during closed-loop induction of anesthesia. (August 2020)
- Record Type:
- Journal Article
- Title:
- The effect of cardiac output on the pharmacokinetics and pharmacodynamics of propofol during closed-loop induction of anesthesia. (August 2020)
- Main Title:
- The effect of cardiac output on the pharmacokinetics and pharmacodynamics of propofol during closed-loop induction of anesthesia
- Authors:
- Savoca, A.
van Heusden, K.
Manca, D.
Ansermino, J.M.
Dumont, G.A. - Abstract:
- Highlights: Hemodynamic effects of closed-loop propofol induction of anesthesia are quantified. Intra-operative hemodynamic changes alter pharmacokinetics and pharmacodynamics. Neglecting these effects leads to dangerous propofol overdosing and deep anesthesia. PBPK simulations can investigate hemodynamic changes impact on depth of hypnosis. The proposed model is a proper tool to study/improve hemodynamics management. Abstract: Background and objective: Intraoperative hemodynamic stability is essential to safety and post-operative well-being of patients and should be optimized in closed-loop control of anesthesia. Cardiovascular changes inducing variations in pharmacokinetics may require dose modification. Rigorous investigational tools can strengthen current knowledge of the anesthesiologists and support clinical practice. We quantify the cardiovascular response of high-risk patients to closed-loop anesthesia and propose a new application of physiologically-based pharmacokinetic-pharmacodynamic (PBPK-PD) simulations to examine the effect of hemodynamic changes on the depth of hypnosis (DoH). Methods: We evaluate clinical hemodynamic changes in response to anesthesia induction in high-risk patients from a study on closed-loop anesthesia. We develop and validate a PBPK-PD model to simulate the effect of changes in cardiac output (CO) on plasma levels and DoH. The wavelet-based anesthetic value for central nervous system monitoring index (WAVCNS ) is used as clinical end-pointHighlights: Hemodynamic effects of closed-loop propofol induction of anesthesia are quantified. Intra-operative hemodynamic changes alter pharmacokinetics and pharmacodynamics. Neglecting these effects leads to dangerous propofol overdosing and deep anesthesia. PBPK simulations can investigate hemodynamic changes impact on depth of hypnosis. The proposed model is a proper tool to study/improve hemodynamics management. Abstract: Background and objective: Intraoperative hemodynamic stability is essential to safety and post-operative well-being of patients and should be optimized in closed-loop control of anesthesia. Cardiovascular changes inducing variations in pharmacokinetics may require dose modification. Rigorous investigational tools can strengthen current knowledge of the anesthesiologists and support clinical practice. We quantify the cardiovascular response of high-risk patients to closed-loop anesthesia and propose a new application of physiologically-based pharmacokinetic-pharmacodynamic (PBPK-PD) simulations to examine the effect of hemodynamic changes on the depth of hypnosis (DoH). Methods: We evaluate clinical hemodynamic changes in response to anesthesia induction in high-risk patients from a study on closed-loop anesthesia. We develop and validate a PBPK-PD model to simulate the effect of changes in cardiac output (CO) on plasma levels and DoH. The wavelet-based anesthetic value for central nervous system monitoring index (WAVCNS ) is used as clinical end-point of propofol hypnotic effect. Results: The median (interquartile range, IQR) changes in CO and arterial pressure (AP), 3 min after induction of anesthesia, are 22.43 (14.82-36.0) % and 26.60 (22.39-35.33) % respectively. The decrease in heart rate (HR) is less marked, i.e. 8.82 (4.94-12.68) %. The cardiovascular response is comparable or less enhanced than in manual propofol induction studies. PBPK simulations show that the marked decrease in CO coincides with high predicted plasma levels and deep levels of hypnosis, i.e. WAVCNS < 40. PD model identification is improved using the PBPK model rather than a standard three-compartment PK model. PD simulations reveal that a 30% drop in CO can cause a 30% change in WAVCNS . Conclusions: Significant CO drops produce increased predicted plasma concentrations corresponding to deeper anesthesia, which is potentially dangerous for elderly patients. PBPK-PD model simulations allow studying and quantifying these effects to improve clinical practice. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 192(2020)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 192(2020)
- Issue Display:
- Volume 192, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 192
- Issue:
- 2020
- Issue Sort Value:
- 2020-0192-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-08
- Subjects:
- Cardiac output -- Hemodynamics -- Closed-loop anesthesia -- Physiologically-based pharmacokinetic modeling -- Propofol -- High-risk patients
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2020.105406 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13530.xml