D-PLEX100 in an Abdominal Surgery Incision Model in Miniature Swine: Safety Study. (July 2020)
- Record Type:
- Journal Article
- Title:
- D-PLEX100 in an Abdominal Surgery Incision Model in Miniature Swine: Safety Study. (July 2020)
- Main Title:
- D-PLEX100 in an Abdominal Surgery Incision Model in Miniature Swine: Safety Study
- Authors:
- Ramot, Yuval
Nedvetzki, Shlomo
Rosenfeld, Sefi
Rousselle, Serge D.
Nyska, Abraham
Emanuel, Noam - Abstract:
- Surgical site infections (SSIs) are a common surgical-related complication. To avoid these complications, a new biodegradable polymer–lipid encapsulation matrix that provides controlled release of doxycycline (doxycycline/polymer-lipid encapsulation matrix [D-PLEX]) has been developed. The aim of this comprehensive study was to evaluate the potential safety of D-PLEX100 in abdominal surgical site. D-PLEX100 was administered into incisions of abdominal surgical site in Yucatan miniature swine, which were followed for up to 6 months and compared to sham-control swine. The D-PLEX100 mass did not migrate from the incisional site, and there was no evidence for systemic toxicity or other safety concerns. Surgical incision sites, including the peritoneal surface, were fully healed at 6 months in all animals. Most of the D-PLEX100 mass was absorbed during the first 3 months, and by 6 months, D-PLEX100 was fully absorbed. Toxicokinetic evaluation revealed that doxycycline concentrations were evident at 30 minutes and persisted to 8 days (71 mg/kg) or at least 15 days (284 mg/kg) and were no longer present in plasma by day 29. This study supports the safety of D-PLEX100 and its favorable degradability profile. A clinical study is being performed to assess the safety and the efficacy of D-PLEX100 to prevent human abdominal SSIs.
- Is Part Of:
- Toxicologic pathology. Volume 48:Number 5(2020)
- Journal:
- Toxicologic pathology
- Issue:
- Volume 48:Number 5(2020)
- Issue Display:
- Volume 48, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 48
- Issue:
- 5
- Issue Sort Value:
- 2020-0048-0005-0000
- Page Start:
- 677
- Page End:
- 685
- Publication Date:
- 2020-07
- Subjects:
- preclinical trials -- biodegradability -- safety evaluation -- drug delivery system -- miniature swine -- surgical site infection
Pathology -- Periodicals
Toxicology -- Periodicals
Pathology
Toxicology
615.9 - Journal URLs:
- http://tpx.sagepub.com/ ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/0192623320928902 ↗
- Languages:
- English
- ISSNs:
- 0192-6233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8873.015000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13532.xml