Biomechanical comparison of knotless vs. knotted suture anchors in the acetabular rim with respect to bone density. (April 2020)
- Record Type:
- Journal Article
- Title:
- Biomechanical comparison of knotless vs. knotted suture anchors in the acetabular rim with respect to bone density. (April 2020)
- Main Title:
- Biomechanical comparison of knotless vs. knotted suture anchors in the acetabular rim with respect to bone density
- Authors:
- Benca, Emir
Dlaska, Constantin E.
DiFranco, Matthew D.
Hobusch, Gerhard M.
Windhager, Reinhard
Angeli, Thomas
von Skrbensky, Gobert - Abstract:
- Abstract: Background: Acetabular labral tears are managed with suture anchors providing good clinical outcomes. Knotless anchors are easier to use and have a quicker insertion time compared to knotted anchors. The purpose of this study was to compare the biomechanical behavior of two different anchor designs (knotted vs. knotless) in ultimate load testing in correlation with bone density in the acetabular rim. Methods: Eighteen knotted Bio-FASTak and seventeen knotless PushLock anchors (both: Arthrex Inc., Naples, FL, USA) were inserted in the rims of two human acetabula, with known bone density distribution. The anchors were subjected to load-to-failure tests. Anchors were additionally tested in solid polyurethane foam with defined densities. Findings: The Bio-FASTak group showed higher survival rates at 1, 2, and 3 mm displacement and was able to withstand significantly higher loads at 3 mm displacement ( p = 0.031). There was no statistically significant difference in stiffness ( p = 0.087), yield- ( p = 0.190), and ultimate load ( p = 0.222) between the two groups. Only the PushLock group showed correlation between bone volume over total volume (BV/TV) and stiffness ( R = 0.750, p = 0.086) and between BV/TV and yield load ( R = 0.838, p = 0.037). Experiments on solid polyurethane foam confirmed the correlation between the mechanical properties and tissue density for the same anchor. Interpretation: PushLock shows similar biomechanical properties to theAbstract: Background: Acetabular labral tears are managed with suture anchors providing good clinical outcomes. Knotless anchors are easier to use and have a quicker insertion time compared to knotted anchors. The purpose of this study was to compare the biomechanical behavior of two different anchor designs (knotted vs. knotless) in ultimate load testing in correlation with bone density in the acetabular rim. Methods: Eighteen knotted Bio-FASTak and seventeen knotless PushLock anchors (both: Arthrex Inc., Naples, FL, USA) were inserted in the rims of two human acetabula, with known bone density distribution. The anchors were subjected to load-to-failure tests. Anchors were additionally tested in solid polyurethane foam with defined densities. Findings: The Bio-FASTak group showed higher survival rates at 1, 2, and 3 mm displacement and was able to withstand significantly higher loads at 3 mm displacement ( p = 0.031). There was no statistically significant difference in stiffness ( p = 0.087), yield- ( p = 0.190), and ultimate load ( p = 0.222) between the two groups. Only the PushLock group showed correlation between bone volume over total volume (BV/TV) and stiffness ( R = 0.750, p = 0.086) and between BV/TV and yield load ( R = 0.838, p = 0.037). Experiments on solid polyurethane foam confirmed the correlation between the mechanical properties and tissue density for the same anchor. Interpretation: PushLock shows similar biomechanical properties to the Bio-FASTak, but eliminates knot tying and potentially abrasive knots. In addition, biomechanical properties of the PushLock are governed by local bone density. Highlights: PushLock eliminates knot tying and potentially abrasive knots. PushLock shows similar biomechanical behavior to the Bio-FASTak. Biomechanical behavior of the PushLock is governed by local bone density. Results were confirmed in tests in solid polyurethane foam. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 74(2020)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 74(2020)
- Issue Display:
- Volume 74, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 74
- Issue:
- 2020
- Issue Sort Value:
- 2020-0074-2020-0000
- Page Start:
- 21
- Page End:
- 26
- Publication Date:
- 2020-04
- Subjects:
- Hip -- Suture anchors -- Acetabular labrum -- Labrum refixation -- Bone density
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2020.02.005 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13504.xml