AED and text message responders density in residential areas for rapid response in out-of-hospital cardiac arrest. (May 2020)
- Record Type:
- Journal Article
- Title:
- AED and text message responders density in residential areas for rapid response in out-of-hospital cardiac arrest. (May 2020)
- Main Title:
- AED and text message responders density in residential areas for rapid response in out-of-hospital cardiac arrest
- Authors:
- Stieglis, Remy
Zijlstra, Jolande A.
Riedijk, Frank
Smeekes, Martin
van der Worp, Wim E.
Koster, Rudolph W. - Abstract:
- Abstract: Background: For out-of-hospital cardiac arrest (OHCA) in residential areas, a dispatcher driven alert-system using text messages (TM-system) directing local rescuers (TM-responders) to OHCA patients was implemented and the desired density of automated external defibrillators (AEDs) or TM-responders investigated. Methods: We included OHCA cases with the TM-system activated in residential areas between 2010–2017. For each case, densities/km 2 of activated AEDs and TM-responders within a 1000 m circle were calculated. Time intervals between 112-call and first defibrillation were calculated. Results: In total, 813 patients (45%) had a shockable initial rhythm. In 17% a TM-system AED delivered the first shock. With increasing AED density, the median time to shock decreased from 10:59 to 08:17 min. (p < 0.001) and shocks <6 min increased from 6% to 12% (p = 0.024). Increasing density of TM-responders was associated with a decrease in median time to shock from 10:59 to 08:20 min. (p < 0.001) and increase of shocks <6 min from 6% to 13% (p = 0.005). Increasing density of AEDs and TM-responders resulted in a decline of ambulance first defibrillation by 19% (p = 0.016) and 22% (p = 0.001), respectively. First responder AED defibrillation did not change significantly. Densities of >2 AEDs/km 2 did not result in further decrease of time to first shock but >10 TM-responders/km 2 resulted in more defibrillations <6 min. Conclusion: With increasing AED and TM-responder densityAbstract: Background: For out-of-hospital cardiac arrest (OHCA) in residential areas, a dispatcher driven alert-system using text messages (TM-system) directing local rescuers (TM-responders) to OHCA patients was implemented and the desired density of automated external defibrillators (AEDs) or TM-responders investigated. Methods: We included OHCA cases with the TM-system activated in residential areas between 2010–2017. For each case, densities/km 2 of activated AEDs and TM-responders within a 1000 m circle were calculated. Time intervals between 112-call and first defibrillation were calculated. Results: In total, 813 patients (45%) had a shockable initial rhythm. In 17% a TM-system AED delivered the first shock. With increasing AED density, the median time to shock decreased from 10:59 to 08:17 min. (p < 0.001) and shocks <6 min increased from 6% to 12% (p = 0.024). Increasing density of TM-responders was associated with a decrease in median time to shock from 10:59 to 08:20 min. (p < 0.001) and increase of shocks <6 min from 6% to 13% (p = 0.005). Increasing density of AEDs and TM-responders resulted in a decline of ambulance first defibrillation by 19% (p = 0.016) and 22% (p = 0.001), respectively. First responder AED defibrillation did not change significantly. Densities of >2 AEDs/km 2 did not result in further decrease of time to first shock but >10 TM-responders/km 2 resulted in more defibrillations <6 min. Conclusion: With increasing AED and TM-responder density within a TM-system, time to defibrillation in residential areas decreased. AED and TM-responders only competed with ambulances, not with first responders. The recommended density of AEDs and TM-responders for earliest defibrillation is 2 AEDs/km 2 and >10 TM-responders/km 2 . … (more)
- Is Part Of:
- Resuscitation. Volume 150(2020)
- Journal:
- Resuscitation
- Issue:
- Volume 150(2020)
- Issue Display:
- Volume 150, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 150
- Issue:
- 2020
- Issue Sort Value:
- 2020-0150-2020-0000
- Page Start:
- 170
- Page End:
- 177
- Publication Date:
- 2020-05
- Subjects:
- Heart arrest -- Ventricular fibrillation -- Defibrillation -- Cardiopulmonary resuscitation -- Lay rescuer -- Text message -- Automated external defibrillator -- AED -- First responder -- Dispatch -- Emergency medical service
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2020.01.031 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13504.xml