Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Issue 126 (May 2020)
- Record Type:
- Journal Article
- Title:
- Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Issue 126 (May 2020)
- Main Title:
- Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT
- Authors:
- Sawall, S.
Klein, L.
Amato, C.
Wehrse, E.
Dorn, S.
Maier, J.
Heinze, S.
Schlemmer, H.-P.
Ziener, C.H.
Uhrig, M.
Kachelrieß, M. - Abstract:
- Highlights: All patients benefit from the favorable properties of photon-counting CT detectors. Photon-counting CT will allow for a radiation dose reduction of up to 46 %. Patients will benefit from a reduction of administered contrast media volume. Abstract: Purpose: To assess the dose-normalized iodine contrast-to-noise-ratio (CNRD) improvement and contrast media reduction potential obtained with photon-counting (PC) CT compared to conventional energy-integrating (EI) CT as a function of patient size and tube voltage. Method: Images of a semi-anthropomorphic phantom of different sizes (small, medium, large) equipped with vials containing different iodine concentrations were acquired at the SOMATOM CounT prototype CT system using tube voltages of 80 kV–140 kV. CNRD is evaluated in reconstructions obtained using the EI detector, the PC detector using a single bin, and in reconstructions obtained by statistically optimally weighting acquisitions with two bins. Iodine CNRD improvements, potential dose reduction and the potential contrast media volume reduction are reported. Results: In general, iodine CNRD improvement increases with increasing tube voltage for all patient sizes. In particular, if only one energy bin is used, the CNRD improvement is up to 30 % (small: 10 %, medium: 18 %, large: 30 %) and up to 37 % if an optimal weighting of two bins is performed (small: 13 %, medium: 25 %, large: 37 %) which is equivalent to the potential contrast media volume reduction. TheHighlights: All patients benefit from the favorable properties of photon-counting CT detectors. Photon-counting CT will allow for a radiation dose reduction of up to 46 %. Patients will benefit from a reduction of administered contrast media volume. Abstract: Purpose: To assess the dose-normalized iodine contrast-to-noise-ratio (CNRD) improvement and contrast media reduction potential obtained with photon-counting (PC) CT compared to conventional energy-integrating (EI) CT as a function of patient size and tube voltage. Method: Images of a semi-anthropomorphic phantom of different sizes (small, medium, large) equipped with vials containing different iodine concentrations were acquired at the SOMATOM CounT prototype CT system using tube voltages of 80 kV–140 kV. CNRD is evaluated in reconstructions obtained using the EI detector, the PC detector using a single bin, and in reconstructions obtained by statistically optimally weighting acquisitions with two bins. Iodine CNRD improvements, potential dose reduction and the potential contrast media volume reduction are reported. Results: In general, iodine CNRD improvement increases with increasing tube voltage for all patient sizes. In particular, if only one energy bin is used, the CNRD improvement is up to 30 % (small: 10 %, medium: 18 %, large: 30 %) and up to 37 % if an optimal weighting of two bins is performed (small: 13 %, medium: 25 %, large: 37 %) which is equivalent to the potential contrast media volume reduction. The improved iodine CNRD of PC compared to EI may allow for a potential radiation dose reduction of up to 46 %. Conclusions: All patients' iodine contrast at given x-ray dose, and particularly medium and large sized patients acquired at higher tube voltages, may benefit from photon-counting CT. The iodine contrast improvement can be used to reduce patient dose or to reduce the amount of contrast agent that is administered. … (more)
- Is Part Of:
- European journal of radiology. Issue 126(2020)
- Journal:
- European journal of radiology
- Issue:
- Issue 126(2020)
- Issue Display:
- Volume 126, Issue 126 (2020)
- Year:
- 2020
- Volume:
- 126
- Issue:
- 126
- Issue Sort Value:
- 2020-0126-0126-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-05
- Subjects:
- Tomography -- X-Ray computed -- Contrast media -- Phantoms -- Imaging -- Radiation dosage
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2020.108909 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13507.xml