The speech intelligibility and applicability of the speech transmission index in large spaces. (October 2020)
- Record Type:
- Journal Article
- Title:
- The speech intelligibility and applicability of the speech transmission index in large spaces. (October 2020)
- Main Title:
- The speech intelligibility and applicability of the speech transmission index in large spaces
- Authors:
- Liu, Hongshan
Ma, Hui
Kang, Jian
Wang, Chao - Abstract:
- Abstract: This paper aims to explore the influence factors of speech intelligibility and the applicability of the speech transmission index (STI) in large spaces, where the sound energy is unevenly distributed and non-exponentially decays. The subjective speech intelligibility tests were conducted in Mandarin (China mainland) in two large spaces with volumes of 97, 000 m 3 and 246, 000 m 3 . Objective indicators such as the Reverberation Time (RT), Early Decay Time (EDT), Definition (D50 ), and Speech Transmission Index (STI) under different signal-to-noise ratio (SNRs) were also measured in these two spaces. The results showed that both the SNR and room acoustics had significant effect on the speech intelligibility in these two spaces, but the effect of room acoustics on speech intelligibility was also affected by SNR. The speech intelligibility scores significantly increased with the increase in SNR when the SNR was less than 14.4 dB. In terms of room acoustics, D50 was more relevant to speech intelligibility than RT and EDT in these two large spaces when SNR ranged from −5dB to 15 dB. The STI value in large spaces should not be used as in ordinary spaces to evaluate the speech intelligibility. Based on the tests in this paper, the corresponding relation between STI and speech intelligibility in large spaces was modified, and a new rating threshold of STI was also proposed according to the revised relation, which indicated a necessity to modify the rating criteria of usingAbstract: This paper aims to explore the influence factors of speech intelligibility and the applicability of the speech transmission index (STI) in large spaces, where the sound energy is unevenly distributed and non-exponentially decays. The subjective speech intelligibility tests were conducted in Mandarin (China mainland) in two large spaces with volumes of 97, 000 m 3 and 246, 000 m 3 . Objective indicators such as the Reverberation Time (RT), Early Decay Time (EDT), Definition (D50 ), and Speech Transmission Index (STI) under different signal-to-noise ratio (SNRs) were also measured in these two spaces. The results showed that both the SNR and room acoustics had significant effect on the speech intelligibility in these two spaces, but the effect of room acoustics on speech intelligibility was also affected by SNR. The speech intelligibility scores significantly increased with the increase in SNR when the SNR was less than 14.4 dB. In terms of room acoustics, D50 was more relevant to speech intelligibility than RT and EDT in these two large spaces when SNR ranged from −5dB to 15 dB. The STI value in large spaces should not be used as in ordinary spaces to evaluate the speech intelligibility. Based on the tests in this paper, the corresponding relation between STI and speech intelligibility in large spaces was modified, and a new rating threshold of STI was also proposed according to the revised relation, which indicated a necessity to modify the rating criteria of using STI to predict speech intelligibility in large spaces. … (more)
- Is Part Of:
- Applied acoustics. Volume 167(2020)
- Journal:
- Applied acoustics
- Issue:
- Volume 167(2020)
- Issue Display:
- Volume 167, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 167
- Issue:
- 2020
- Issue Sort Value:
- 2020-0167-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Speech intelligibility -- Speech transmission index -- Large spaces
Acoustical engineering -- Periodicals
Periodicals
620.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0003682X ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/homepage/elecserv.htt ↗ - DOI:
- 10.1016/j.apacoust.2020.107400 ↗
- Languages:
- English
- ISSNs:
- 0003-682X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1571.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13498.xml