Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial. Issue 2 (April 2020)
- Record Type:
- Journal Article
- Title:
- Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial. Issue 2 (April 2020)
- Main Title:
- Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial
- Authors:
- Arcuri, Lorenzo
Pozzi, Alessandro
Lio, Fabrizio
Rompen, Eric
Zechner, Werner
Nardi, Alessandra - Abstract:
- Abstract: Purpose: To evaluate the influence of implant scanbody (ISB) material, position and operator on the accuracy of a confocal microscopy intraoral scanning (IOS) for complete-arch implant impression. Methods: An edentulous maxillary model with 6 internal hexagonal connection analogues was scanned with an extraoral optical scanner to achieve a reference file. Three ISBs made of different materials (polyetheretherketone (Pk), titanium (T) and Pk with a titanium base (Pkt)) were scanned with IOS by 3 operators. The resulting 45 test files were aligned to the reference file with a best fit algorithm. Linear (ΔX, ΔY and ΔZ-axis) and angular deviations (ΔANGLE) were assessed. Absolute values of the linear discrepancies were summed up to obtain a global measure of linear absolute error (ΔASS). Influence of ISB material, position and operator was statistically assessed using the mixed general linear model. Results: At multivariate analysis, whenΔASS was considered as response variable, it was identified a significant influence of material ( p < 0.0001) and position ( p = 0.0009) while no significant operator effect was detected. When ΔANGLE was considered as response variable, material and position significantly influenced the expected ΔANGLE ( p = 0.0232 and p < 0.0001) and no operator effect was identified. Conclusions: The investigated IOS for complete-arch digital impression was influenced by the ISB material with peek reporting the best results on both linear andAbstract: Purpose: To evaluate the influence of implant scanbody (ISB) material, position and operator on the accuracy of a confocal microscopy intraoral scanning (IOS) for complete-arch implant impression. Methods: An edentulous maxillary model with 6 internal hexagonal connection analogues was scanned with an extraoral optical scanner to achieve a reference file. Three ISBs made of different materials (polyetheretherketone (Pk), titanium (T) and Pk with a titanium base (Pkt)) were scanned with IOS by 3 operators. The resulting 45 test files were aligned to the reference file with a best fit algorithm. Linear (ΔX, ΔY and ΔZ-axis) and angular deviations (ΔANGLE) were assessed. Absolute values of the linear discrepancies were summed up to obtain a global measure of linear absolute error (ΔASS). Influence of ISB material, position and operator was statistically assessed using the mixed general linear model. Results: At multivariate analysis, whenΔASS was considered as response variable, it was identified a significant influence of material ( p < 0.0001) and position ( p = 0.0009) while no significant operator effect was detected. When ΔANGLE was considered as response variable, material and position significantly influenced the expected ΔANGLE ( p = 0.0232 and p < 0.0001) and no operator effect was identified. Conclusions: The investigated IOS for complete-arch digital impression was influenced by the ISB material with peek reporting the best results on both linear and angular measurements followed by titanium, peek-titanium resulting as the less accurate. Implant angulation affected significantly the linear deviations while implant position the angular deviations. Operator did not show any significant effect on the IOS accuracy. … (more)
- Is Part Of:
- Journal of prosthodontic research. Volume 64:Issue 2(2020)
- Journal:
- Journal of prosthodontic research
- Issue:
- Volume 64:Issue 2(2020)
- Issue Display:
- Volume 64, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 64
- Issue:
- 2
- Issue Sort Value:
- 2020-0064-0002-0000
- Page Start:
- 128
- Page End:
- 136
- Publication Date:
- 2020-04
- Subjects:
- Implant scanbody -- Peek -- Ios -- Digital impression -- Complete-arch
Prosthodontics -- Periodicals
Dentistry -- Periodicals
Prosthodontics -- Periodicals
Electronic journals
Computer network resources
617.6905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18831958 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jpor.2019.06.001 ↗
- Languages:
- English
- ISSNs:
- 1883-1958
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.915000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13494.xml