Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study. (March 2020)
- Record Type:
- Journal Article
- Title:
- Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study. (March 2020)
- Main Title:
- Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study
- Authors:
- Robinson, Dale L.
Safai, Lauren
Harandi, Vahidreza Jafari
Graf, Mark
Lizama, L. Eduardo Cofré
Lee, Peter
Galea, Mary P.
Khan, Fary
Tse, Kwong Ming
Ackland, David C. - Abstract:
- Abstract: Background: Osseointegrated implants for transfemoral amputees facilitate direct load transfer between the prosthetic limb and femur; however, implant loosening is a common complication, and the associated implant-bone loads remain poorly understood. This case study aimed to use patient-specific computational modeling to evaluate bone-implant interface loading during standing and walking in a transfemoral amputee with an osseointegrated implant prior to prosthesis loosening and revision surgery. Methods: One male transfemoral amputee with an osseointegrated implant was recruited (age: 59-yrs, weight: 83 kg) and computed tomography (CT) performed on the residual limb approximately 3 months prior to implant failure. Gait analyses were performed, and the CT images used to develop a finite element model of the patient's implant and surrounding bone. Simulations of static weight bearing, and over-ground walking were then performed. Findings: During standing, maximum and minimum principal strains in trabecular bone adjacent to the implant were 0.26% and −0.30%, respectively. Strains generated at the instant of contralateral toe-off and contralateral heel strike during walking were substantially higher and resulted in local trabecular bone yielding. Specifically, the maximum and minimum principal strains in the thin layer of trabecular bone surrounding the distal end of the implant were 1.15% and −0.98%, respectively. Interpretation: Localised yielding of trabecular boneAbstract: Background: Osseointegrated implants for transfemoral amputees facilitate direct load transfer between the prosthetic limb and femur; however, implant loosening is a common complication, and the associated implant-bone loads remain poorly understood. This case study aimed to use patient-specific computational modeling to evaluate bone-implant interface loading during standing and walking in a transfemoral amputee with an osseointegrated implant prior to prosthesis loosening and revision surgery. Methods: One male transfemoral amputee with an osseointegrated implant was recruited (age: 59-yrs, weight: 83 kg) and computed tomography (CT) performed on the residual limb approximately 3 months prior to implant failure. Gait analyses were performed, and the CT images used to develop a finite element model of the patient's implant and surrounding bone. Simulations of static weight bearing, and over-ground walking were then performed. Findings: During standing, maximum and minimum principal strains in trabecular bone adjacent to the implant were 0.26% and −0.30%, respectively. Strains generated at the instant of contralateral toe-off and contralateral heel strike during walking were substantially higher and resulted in local trabecular bone yielding. Specifically, the maximum and minimum principal strains in the thin layer of trabecular bone surrounding the distal end of the implant were 1.15% and −0.98%, respectively. Interpretation: Localised yielding of trabecular bone at the interface between the femur and implant in transfemoral amputee osseointegrated prosthesis recipients may present a risk of implant loosening due to periprosthetic bone fracture during walking. Rehabilitation exercises should aim to produce implant-bone loading that stimulates bone remodelling to provide effective bone conditioning prior to ambulation. Highlights: Osseointegrated transfemoral prosthesis recipient bone strains peak at distal femur. Distal bone yielding contributes to osseointegrated prosthesis failure. Osseointegration bone strains are three times larger during walking than standing. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 73(2020)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 73(2020)
- Issue Display:
- Volume 73, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 73
- Issue:
- 2020
- Issue Sort Value:
- 2020-0073-2020-0000
- Page Start:
- 201
- Page End:
- 212
- Publication Date:
- 2020-03
- Subjects:
- Lower limb amputee -- Osseointegration -- Finite element analysis -- Gait -- Biomechanical model
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2020.01.017 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13502.xml