Feasibility of image registration and fusion for evaluation of structure and perfusion of the entire second trimester placenta by three-dimensional power Doppler ultrasound. (May 2020)
- Record Type:
- Journal Article
- Title:
- Feasibility of image registration and fusion for evaluation of structure and perfusion of the entire second trimester placenta by three-dimensional power Doppler ultrasound. (May 2020)
- Main Title:
- Feasibility of image registration and fusion for evaluation of structure and perfusion of the entire second trimester placenta by three-dimensional power Doppler ultrasound
- Authors:
- Cheung, Winnie
Stevenson, Gordon N.
de Melo Tavares Ferreira, Ana Elizabeth Gomes
Alphonse, Jennifer
Welsh, Alec W. - Abstract:
- Abstract: Background: Placental perfusion can be evaluated by 3D power Doppler ultrasound (3D PD-US), particularly using the validated tool 3D Fractional Moving Blood Volume (3D-FMBV); however regional variability and size limitations beyond the first trimester mean that multiple 3D PD-US volumes are required to evaluate the whole organ. Purpose: We assessed the feasibility of manual offline stitching of second trimester 3D PD-US volumes of the placenta to assess whole organ perfusion using 3D-FMBV. Materials and methods: This was a single-centre, prospective, observational cohort study of 36 normal second trimester singleton pregnancies with anterior placentas. 3D PD-US placental volumes were manually segmented offline and stitched together by rigid registration using manually selected, pair-wise coordinates. Data acquisition and offline volume segmentation and stitching were triplicated by a single observer with Dice similarity coefficient (DSC) and Hausdorff distance used to assess consistency. Intraclass correlation coefficient (ICC) was used to assess intra-observer repeatability of 3D-FMBV and placental volume. Results: Acquisition and stitching success were 94% and 88%, respectively. Median time for acquisition, segmentation and stitching were 13 min, 40 min and 95 min, respectively. Median intra-observer DSCs were 0.94 and 0.88, and Hausdorff distances were 11.85 mm and 36.6 mm, for segmentations and stitching, respectively. Conclusion: 3D-ultrasound volume stitchingAbstract: Background: Placental perfusion can be evaluated by 3D power Doppler ultrasound (3D PD-US), particularly using the validated tool 3D Fractional Moving Blood Volume (3D-FMBV); however regional variability and size limitations beyond the first trimester mean that multiple 3D PD-US volumes are required to evaluate the whole organ. Purpose: We assessed the feasibility of manual offline stitching of second trimester 3D PD-US volumes of the placenta to assess whole organ perfusion using 3D-FMBV. Materials and methods: This was a single-centre, prospective, observational cohort study of 36 normal second trimester singleton pregnancies with anterior placentas. 3D PD-US placental volumes were manually segmented offline and stitched together by rigid registration using manually selected, pair-wise coordinates. Data acquisition and offline volume segmentation and stitching were triplicated by a single observer with Dice similarity coefficient (DSC) and Hausdorff distance used to assess consistency. Intraclass correlation coefficient (ICC) was used to assess intra-observer repeatability of 3D-FMBV and placental volume. Results: Acquisition and stitching success were 94% and 88%, respectively. Median time for acquisition, segmentation and stitching were 13 min, 40 min and 95 min, respectively. Median intra-observer DSCs were 0.94 and 0.88, and Hausdorff distances were 11.85 mm and 36.6 mm, for segmentations and stitching, respectively. Conclusion: 3D-ultrasound volume stitching of the placenta is technically feasible. Intra-observer repeatability was good to excellent for all measured parameters. This work demonstrates technical feasibility; further studies may provide the basis of an in-vivo assessment tool to measure the placenta in mid-to late pregnancy. Highlights: Article Highlights. Demonstrates use of image processing to show whole placental perfusion in mid-late pregnancy using 3D ultrasound (3D-US). The technique shows good intra-observer repeatability for all measured parameters (ICCs > 0.82). Triplication of labelling of the placenta led to excellent repeatability when measured by similarity metrics. … (more)
- Is Part Of:
- Placenta. Volume 94(2020)
- Journal:
- Placenta
- Issue:
- Volume 94(2020)
- Issue Display:
- Volume 94, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 94
- Issue:
- 2020
- Issue Sort Value:
- 2020-0094-2020-0000
- Page Start:
- 13
- Page End:
- 19
- Publication Date:
- 2020-05
- Subjects:
- Imaging -- Three-dimensional -- Pregnancy trimester -- Second -- Placental circulation -- Placenta -- Diagnostic imaging* -- Ultrasonography -- Doppler
3D Three Dimensional -- CoV Coefficient of Variation -- DSC Dice Similarity Coefficient -- FMBV Fractional Moving Blood Volume -- ICC Intra-class Correlation Coefficients -- IVS Inter-villous Space -- PD Power Doppler -- NIFTI Neuroimaging Informatics Technology Initiative -- UPI Utero-Placental Interface
Placenta -- Periodicals
Reproduction -- Periodicals
Placenta -- Periodicals
Placenta -- Périodiques
Reproduction -- Périodiques
612.63 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01434004 ↗
http://www.placentajournal.org/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01434004 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01434004 ↗
http://www.elsevier.com/journals ↗
http://www.harcourt-international.com/journals/plac/ ↗
http://www.idealibrary.com/cgi-bin/links/toc/plac ↗
http://www.harcourt-international.com/journals ↗ - DOI:
- 10.1016/j.placenta.2020.03.005 ↗
- Languages:
- English
- ISSNs:
- 0143-4004
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6506.800000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13495.xml