Dosimetric evaluation of neutron contamination caused by dental restorations during photon radiotherapy with a 15 MV Siemens Primus linear accelerator. (September 2020)
- Record Type:
- Journal Article
- Title:
- Dosimetric evaluation of neutron contamination caused by dental restorations during photon radiotherapy with a 15 MV Siemens Primus linear accelerator. (September 2020)
- Main Title:
- Dosimetric evaluation of neutron contamination caused by dental restorations during photon radiotherapy with a 15 MV Siemens Primus linear accelerator
- Authors:
- Ghorbani, Mahdi
Azizi, Mona
Azadegan, Behnam
Mowlavi, Ali Asghar
Rahvar, Zeinab Alizadeh
Wagner, Wolfgang - Abstract:
- Abstract: The investigation of neutron contamination during radiotherapy by means of high-energy photon beams is a clinically important task. The present study aims to evaluate neutron contamination originating from the presence of various dental restorations, such as a tooth restored with amalgam, a tooth restored with Ni-Cr alloy, and a tooth restored with Ceramco. Using the MCNPX Monte Carlo code, we calculated the neutron contamination relative to the dose deposited in a water phantom at various penetration depths on the central axis of a photon beam provided by a 15 MV Siemens Primus linear accelerator operating in photon mode. Calculation of the energy spectrum of neutrons produced by the Siemens Primus linear accelerator revealed a peak at about 1 MeV. Dental restorations led to a maximum percentage neutron dose increase at a depth of 2.30 cm of 26.78%, 18.75%, and 10.71% for a tooth restored with amalgam, a tooth restored with Ceramco, and a tooth restored with Ni-Cr alloy, respectively, compared with 5.35% for a healthy tooth. Since the percentage neutron dose depends on the cross section of the photonuclear reaction with the restoration material and, hence, on the reaction energy threshold, underestimation of the dose in treatment planning may occur, especially if restoration materials of high atomic number are used. The fast-neutron equivalent dose for water decreases with increasing depth. For dental restorations with amalgam, Ceramco, and Ni-Cr alloy, it reachesAbstract: The investigation of neutron contamination during radiotherapy by means of high-energy photon beams is a clinically important task. The present study aims to evaluate neutron contamination originating from the presence of various dental restorations, such as a tooth restored with amalgam, a tooth restored with Ni-Cr alloy, and a tooth restored with Ceramco. Using the MCNPX Monte Carlo code, we calculated the neutron contamination relative to the dose deposited in a water phantom at various penetration depths on the central axis of a photon beam provided by a 15 MV Siemens Primus linear accelerator operating in photon mode. Calculation of the energy spectrum of neutrons produced by the Siemens Primus linear accelerator revealed a peak at about 1 MeV. Dental restorations led to a maximum percentage neutron dose increase at a depth of 2.30 cm of 26.78%, 18.75%, and 10.71% for a tooth restored with amalgam, a tooth restored with Ceramco, and a tooth restored with Ni-Cr alloy, respectively, compared with 5.35% for a healthy tooth. Since the percentage neutron dose depends on the cross section of the photonuclear reaction with the restoration material and, hence, on the reaction energy threshold, underestimation of the dose in treatment planning may occur, especially if restoration materials of high atomic number are used. The fast-neutron equivalent dose for water decreases with increasing depth. For dental restorations with amalgam, Ceramco, and Ni-Cr alloy, it reaches maximum values beyond the dental phantom of 1.28, 1.15, and 0.94 mSv, respectively. The maximum values of the thermal-neutron equivalent dose beyond the dental phantom are 1.32, 1.23, and 1.16 mSv for amalgam, Ceramco, and Ni-Cr alloy, respectively. Highlights: Various dental restorations lead to an increase of neutron dose. The neutron contamination depends on the in-phantom depth. The neutron contamination depends on the composition of the restoration material. The maximum fast-neutron dose is for tooth restored with amalgam. The minimum thermal-neutron dose is for tooth restored with Ni-Cr alloy. … (more)
- Is Part Of:
- Radiation physics and chemistry. Volume 174(2020:Sep.)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 174(2020:Sep.)
- Issue Display:
- Volume 174 (2020)
- Year:
- 2020
- Volume:
- 174
- Issue Sort Value:
- 2020-0174-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- Neutron contamination -- Dental restoration -- Photon beam -- Medical linac -- Monte Carlo code
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2020.108961 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13491.xml