Squeaking and other noises in patients with ceramic-on-ceramic total hip arthroplasty. Issue 4 (July 2020)
- Record Type:
- Journal Article
- Title:
- Squeaking and other noises in patients with ceramic-on-ceramic total hip arthroplasty. Issue 4 (July 2020)
- Main Title:
- Squeaking and other noises in patients with ceramic-on-ceramic total hip arthroplasty
- Authors:
- Baruffaldi, Fabio
Mecca, Rosaria
Stea, Susanna
Beraudi, Alina
Bordini, Barbara
Amabile, Marilina
Sudanese, Alessandra
Toni, Aldo - Abstract:
- Introduction: Noise in ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a potential symptom of abnormal bearing wear. Squeaking and other prosthetic hip noises are multi-factorial phenomena that can be analysed and may provide prognostic information. Methods: 46 patients with noisy CoC bearings were investigated using X-ray, computed tomography and joint fluid analysis, and classified into either high or low risk of ceramic liner fracture groups according to previously published guidelines. Noise events from the bearings of 16 high risk cases which were subsequently revised were compared with 30 patients in the low risk control group who did not undergo revision. Noise events were analysed for their physical characteristics using a standardised protocol and classified as either low frequency and short duration 'clicking' or long duration and high frequency 'squeaking'. Results: The peak frequency of squeaking during forward walking was significantly higher for patients in the case group who were revised, compared with the control group. The patient-reported onset of squeaking (46 months postoperatively) was earlier than short-noise emissions (82 months). In the standardised sequence of movements, short-noise always occurred more frequently than squeaking. Small heads (28 mm) were more likely to develop short-noise, while large heads (⩾32 mm) were more likely to develop squeaking. Discussion: Noise evaluation may provide additional value for predicting failure of CoCIntroduction: Noise in ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a potential symptom of abnormal bearing wear. Squeaking and other prosthetic hip noises are multi-factorial phenomena that can be analysed and may provide prognostic information. Methods: 46 patients with noisy CoC bearings were investigated using X-ray, computed tomography and joint fluid analysis, and classified into either high or low risk of ceramic liner fracture groups according to previously published guidelines. Noise events from the bearings of 16 high risk cases which were subsequently revised were compared with 30 patients in the low risk control group who did not undergo revision. Noise events were analysed for their physical characteristics using a standardised protocol and classified as either low frequency and short duration 'clicking' or long duration and high frequency 'squeaking'. Results: The peak frequency of squeaking during forward walking was significantly higher for patients in the case group who were revised, compared with the control group. The patient-reported onset of squeaking (46 months postoperatively) was earlier than short-noise emissions (82 months). In the standardised sequence of movements, short-noise always occurred more frequently than squeaking. Small heads (28 mm) were more likely to develop short-noise, while large heads (⩾32 mm) were more likely to develop squeaking. Discussion: Noise evaluation may provide additional value for predicting failure of CoC bearings, though some questions should be better investigated in a dedicated prospective trial. … (more)
- Is Part Of:
- Hip international. Volume 30:Issue 4(2020)
- Journal:
- Hip international
- Issue:
- Volume 30:Issue 4(2020)
- Issue Display:
- Volume 30, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 30
- Issue:
- 4
- Issue Sort Value:
- 2020-0030-0004-0000
- Page Start:
- 438
- Page End:
- 445
- Publication Date:
- 2020-07
- Subjects:
- Ceramic-on-ceramic bearing -- noise -- squeaking -- total hip arthroplasty
Hip joint -- Pathophysiology -- Periodicals
Hip joint -- Diseases -- Periodicals
Hip joint -- Surgery -- Periodicals
617.581005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/home/hpi ↗ - DOI:
- 10.1177/1120700019864233 ↗
- Languages:
- English
- ISSNs:
- 1120-7000
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13488.xml