On-line microcolumn-based dynamic leaching method for investigation of lead bioaccessibility in shooting range soils. (October 2020)
- Record Type:
- Journal Article
- Title:
- On-line microcolumn-based dynamic leaching method for investigation of lead bioaccessibility in shooting range soils. (October 2020)
- Main Title:
- On-line microcolumn-based dynamic leaching method for investigation of lead bioaccessibility in shooting range soils
- Authors:
- Joon, Narender Kumar
Ek, Paul
Zevenhoven, Maria
Hupa, Leena
Miró, Manuel
Bobacka, Johan
Lisak, Grzegorz - Abstract:
- Abstract: In this work, a miniaturized flow-through leaching test is presented for rapid screening of potential chemical extractants to explore the bioaccessibility of lead (Pb) in contaminated shooting range soils in Valkeala, Finland. The method combines the versatility of microcolumn-based extraction methods with on-line inductively coupled plasma optical emission spectrometry (ICP OES) analysis for expedient assessment of the magnitude of the bioaccessible pools and the leaching kinetics of lead from polluted soils under variable physicochemical scenarios. Acids and salt solutions were studied as potential extractants. The efficiency of the extractants relative to the initial total amount of lead in the soil sample (509 ± 21 mg/kg) were found to increase in the following order: 0.11 M acetic acid (55%) < 1 M MgCl2 (58%) < 0.1 M NH2 OH·HCl (61%) < 0.1 M citric acid (93%) < 0.1 M HCl (96%). The proposed on-line microcolumn-based method was further explored for implementation of the modified BCR (now termed Standards, Measurements and Testing Programme, SM&T) sequential extraction procedure to avail the information about different fractions available in the solid sample, and validated by mass balance calculations. The equivalent sequential procedure in a batch format was then studied and compared against the on-line microcolumn extraction method. The on-line dynamic extraction system presented in this work accepts a substantial amount of sample (2.5 g) as compared toAbstract: In this work, a miniaturized flow-through leaching test is presented for rapid screening of potential chemical extractants to explore the bioaccessibility of lead (Pb) in contaminated shooting range soils in Valkeala, Finland. The method combines the versatility of microcolumn-based extraction methods with on-line inductively coupled plasma optical emission spectrometry (ICP OES) analysis for expedient assessment of the magnitude of the bioaccessible pools and the leaching kinetics of lead from polluted soils under variable physicochemical scenarios. Acids and salt solutions were studied as potential extractants. The efficiency of the extractants relative to the initial total amount of lead in the soil sample (509 ± 21 mg/kg) were found to increase in the following order: 0.11 M acetic acid (55%) < 1 M MgCl2 (58%) < 0.1 M NH2 OH·HCl (61%) < 0.1 M citric acid (93%) < 0.1 M HCl (96%). The proposed on-line microcolumn-based method was further explored for implementation of the modified BCR (now termed Standards, Measurements and Testing Programme, SM&T) sequential extraction procedure to avail the information about different fractions available in the solid sample, and validated by mass balance calculations. The equivalent sequential procedure in a batch format was then studied and compared against the on-line microcolumn extraction method. The on-line dynamic extraction system presented in this work accepts a substantial amount of sample (2.5 g) as compared to previous flow-through mini-column setups (generally accommodating < 0.25 g of sample), thus maintaining sample representativeness and fostering comprehension of the extraction patterns for non-homogenous soil materials. The use of cotton buds and Teflon membranes and holders in the microcolumn setup facilitates the repeatable flow-through leaching of trace elements and restrict formation of preferential channels. Monitoring of the leachable trace elements in real time delivers detailed insight into the ongoing extraction process and provides a time-saving assessment of potential chemical extractants. Highlights: The microcolumn-based extraction method with on-line ICP OES analysis was developed. Rapid extractants screening for lead removal from contaminated shooting range soils. Monitoring of the leachable trace elements in real time. … (more)
- Is Part Of:
- Chemosphere. Volume 256(2020)
- Journal:
- Chemosphere
- Issue:
- Volume 256(2020)
- Issue Display:
- Volume 256, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 256
- Issue:
- 2020
- Issue Sort Value:
- 2020-0256-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Leaching kinetics -- On-line column extraction -- Real-time metal analysis -- Metal bioaccessibility -- ICP OES assays
Pollution -- Periodicals
Pollution -- Physiological effect -- Periodicals
Environmental sciences -- Periodicals
Atmospheric chemistry -- Periodicals
551.511 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00456535/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.chemosphere.2020.127022 ↗
- Languages:
- English
- ISSNs:
- 0045-6535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3172.280000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13480.xml