Prevalence and prognostic significance of device-detected subclinical atrial fibrillation in patients with heart failure and reduced ejection fraction. (1st August 2020)
- Record Type:
- Journal Article
- Title:
- Prevalence and prognostic significance of device-detected subclinical atrial fibrillation in patients with heart failure and reduced ejection fraction. (1st August 2020)
- Main Title:
- Prevalence and prognostic significance of device-detected subclinical atrial fibrillation in patients with heart failure and reduced ejection fraction
- Authors:
- Zakeri, Rosita
Morgan, John M.
Phillips, Patrick
Kitt, Sue
Ng, G. Andre
McComb, Janet M.
Williams, Simon
Wright, David J.
Gill, Jaswinder S.
Seed, Alison
Witte, Klaus K.
Cowie, Martin R. - Abstract:
- Abstract: Background: Cardiac implanted electronic devices (CIEDs) can detect short durations of previously unrecognised atrial fibrillation (AF). The prognostic significance of device-detected subclinical AF, in the context of contemporary heart failure (HF) therapy, is unclear. Methods: Amongst patients enrolled in the Remote Monitoring in HF with implanted devices (REM-HF) trial, three categories were defined based on total AF duration in the first year of follow-up: no AF, subclinical AF (≥6 min to ≤24 h), and AF >24 h. All-cause mortality, stroke, and cardiovascular hospitalisation were assessed. Results: 1561 patients (94.6%) had rhythm data: 71 (4.6%) had subclinical AF (median of 4 episodes, total duration 3.1 h) and 279 (17.9%) had AF >24 h. During 2.8 ± 0.8 years' follow-up, 39 (2.5%) patients had a stroke. Stroke rate was highest amongst patients with subclinical AF (2.0 per 100-person years) versus no AF or AF >24 h (0.8 and 1.0 per 100-person years, respectively). In the overall cohort, AF >24 h was not an independent predictor of stroke. However, amongst patients with no history of AF (n = 932), new-onset subclinical AF conferred a three-fold higher stroke risk (adjusted HR 3.35, 95%CI 1.15–9.77, p = 0.027). AF >24 h was associated with more frequent emergency cardiovascular hospitalisation (adjusted HR 1.46, 95%CI 1.19–1.79, p < 0.0005). Neither AF classification was associated with mortality. Conclusions: In patients with HF and a CIED, subclinical AF wasAbstract: Background: Cardiac implanted electronic devices (CIEDs) can detect short durations of previously unrecognised atrial fibrillation (AF). The prognostic significance of device-detected subclinical AF, in the context of contemporary heart failure (HF) therapy, is unclear. Methods: Amongst patients enrolled in the Remote Monitoring in HF with implanted devices (REM-HF) trial, three categories were defined based on total AF duration in the first year of follow-up: no AF, subclinical AF (≥6 min to ≤24 h), and AF >24 h. All-cause mortality, stroke, and cardiovascular hospitalisation were assessed. Results: 1561 patients (94.6%) had rhythm data: 71 (4.6%) had subclinical AF (median of 4 episodes, total duration 3.1 h) and 279 (17.9%) had AF >24 h. During 2.8 ± 0.8 years' follow-up, 39 (2.5%) patients had a stroke. Stroke rate was highest amongst patients with subclinical AF (2.0 per 100-person years) versus no AF or AF >24 h (0.8 and 1.0 per 100-person years, respectively). In the overall cohort, AF >24 h was not an independent predictor of stroke. However, amongst patients with no history of AF (n = 932), new-onset subclinical AF conferred a three-fold higher stroke risk (adjusted HR 3.35, 95%CI 1.15–9.77, p = 0.027). AF >24 h was associated with more frequent emergency cardiovascular hospitalisation (adjusted HR 1.46, 95%CI 1.19–1.79, p < 0.0005). Neither AF classification was associated with mortality. Conclusions: In patients with HF and a CIED, subclinical AF was infrequent but, as a new finding, was associated with an increased risk of stroke. Anticoagulation remains an important consideration in this population, particularly when the clinical profile indicates a high stroke risk. Highlights: Subclinical AF occurred in <5% of patients with HF and an implanted device. New-onset subclinical AF was associated with a three-fold increased risk of stroke. AF longer than 24-hours' total duration increased CV hospitalisation risk. AF did not increase the risk of mortality in the context of contemporary HF therapy. … (more)
- Is Part Of:
- International journal of cardiology. Volume 312(2020)
- Journal:
- International journal of cardiology
- Issue:
- Volume 312(2020)
- Issue Display:
- Volume 312, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 312
- Issue:
- 2020
- Issue Sort Value:
- 2020-0312-2020-0000
- Page Start:
- 64
- Page End:
- 70
- Publication Date:
- 2020-08-01
- Subjects:
- Atrial fibrillation -- Heart failure -- Cardiac implanted electronic device -- Stroke
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2020.03.008 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13471.xml