The effect of non-fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine during whole-body vibration. (August 2020)
- Record Type:
- Journal Article
- Title:
- The effect of non-fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine during whole-body vibration. (August 2020)
- Main Title:
- The effect of non-fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine during whole-body vibration
- Authors:
- Fan, Wei
Guo, Li-Xin - Abstract:
- Highlights: Dynamic fixation using the BioFlex system and anterior lumbar interbody fusion (ALIF) with rigid fixation were simulated using finite element method. Stress and strain responses of the healthy, degenerated, BioFlex and ALIF models to vertical vibration loading were computed. Biomechanical differences among these four finite elements models were compared. Abstract: Background and objective: Non-fusion dynamic stabilization surgery is increasingly popular for treating degenerative lumbar disc disease. However, changes in spine biomechanics after application of posterior dynamic fixation devices during whole-body vibration (WBV) remain unclear. The study aimed to examine the effects of non-fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine to vertical WBV. Methods: By modifying L4–L5 segment of the healthy human L1–sacrum finite element model, single-level disc degeneration, dynamic fixation using the BioFlex system and anterior lumbar interbody fusion (ALIF) with rigid fixation were simulated, respectively. Dynamic responses of stress and strain in the spinal levels for the healthy, degenerated, BioFlex and ALIF models under an axial cyclic loading were investigated and compared. Results: The results showed that endplate stress at implant level was lower in the BioFlex model than in the degenerated and ALIF models, but stress of the connecting rod in the BioFlex system was greater than that in the rigid fixation system used in theHighlights: Dynamic fixation using the BioFlex system and anterior lumbar interbody fusion (ALIF) with rigid fixation were simulated using finite element method. Stress and strain responses of the healthy, degenerated, BioFlex and ALIF models to vertical vibration loading were computed. Biomechanical differences among these four finite elements models were compared. Abstract: Background and objective: Non-fusion dynamic stabilization surgery is increasingly popular for treating degenerative lumbar disc disease. However, changes in spine biomechanics after application of posterior dynamic fixation devices during whole-body vibration (WBV) remain unclear. The study aimed to examine the effects of non-fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine to vertical WBV. Methods: By modifying L4–L5 segment of the healthy human L1–sacrum finite element model, single-level disc degeneration, dynamic fixation using the BioFlex system and anterior lumbar interbody fusion (ALIF) with rigid fixation were simulated, respectively. Dynamic responses of stress and strain in the spinal levels for the healthy, degenerated, BioFlex and ALIF models under an axial cyclic loading were investigated and compared. Results: The results showed that endplate stress at implant level was lower in the BioFlex model than in the degenerated and ALIF models, but stress of the connecting rod in the BioFlex system was greater than that in the rigid fixation system used in the ALIF. Compared with the healthy model, stress and strain responses in terms of disc bulge, annulus stress and nucleus pressure at adjacent levels were decreased in the degenerated, BioFlex and ALIF models, but no obvious difference was observed in these responses among the three models. Conclusions: This study may be helpful to understand variations in vibration characteristics of the lumbar spine after application of non-fusion dynamic stabilization system. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 192(2020)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 192(2020)
- Issue Display:
- Volume 192, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 192
- Issue:
- 2020
- Issue Sort Value:
- 2020-0192-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-08
- Subjects:
- Non-fusion -- Dynamic stabilization -- Lumbar spine -- Biomechanical responses -- Whole-body vibration -- Finite element
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2020.105441 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13473.xml