Evaluation of three VMAT-TMI planning methods to find an appropriate balance between plan complexity and the resulting dose distribution. (July 2020)
- Record Type:
- Journal Article
- Title:
- Evaluation of three VMAT-TMI planning methods to find an appropriate balance between plan complexity and the resulting dose distribution. (July 2020)
- Main Title:
- Evaluation of three VMAT-TMI planning methods to find an appropriate balance between plan complexity and the resulting dose distribution
- Authors:
- Litoborska, Joanna
Piotrowski, Tomasz
Malicki, Julian - Abstract:
- Highlights: Relation of dose distribution and plan complexity is a good tool for plans scoring. MU reduction tool used during VMAT-TMI creation reduce complexity of the plan. Simultaneously optimised 8-arcs with MU reduction is recommended for VMAT-TMI. Abstract: Purpose: Evaluation of different planning methods of treatment plan preparation for volumetric modulated arc therapy during total marrow irradiation (VMAT-TMI). Method: Three different planning methods were evaluated to establish the most appropriate VMAT-TMI technique, based on organ at risk (OAR) dose reduction, conformity and plan simplicity. The methods were: (M1 ) the sub-plan method, (M2 ) use of eight arcs optimised simultaneously and (M3 ) M2 with monitor unit reduction. Friedman ANOVA comparison, with Nemenyi's procedures, was used in the statistical analysis of the results. Results: The dosimetric results obtained for the planning target volume and for most OARs do not differ statistically between methods. The M3 method was characterized by the lowest numbers of monitor units (3259 MU vs. 4450 MU for M1 and 4216 MU for M2 ) and, in general, the lowest complexity. The variability of the monitor units from control points was almost half for M3 than M1 and M2 (i.e. 0.33 MU vs . 0.61 MU for M1 and 0.58 for M2 ). Analysing the relationship between the dose distributions obtained for the plans and their complexity, the best result was observed for the M3 method. Conclusion: The use of eight simultaneouslyHighlights: Relation of dose distribution and plan complexity is a good tool for plans scoring. MU reduction tool used during VMAT-TMI creation reduce complexity of the plan. Simultaneously optimised 8-arcs with MU reduction is recommended for VMAT-TMI. Abstract: Purpose: Evaluation of different planning methods of treatment plan preparation for volumetric modulated arc therapy during total marrow irradiation (VMAT-TMI). Method: Three different planning methods were evaluated to establish the most appropriate VMAT-TMI technique, based on organ at risk (OAR) dose reduction, conformity and plan simplicity. The methods were: (M1 ) the sub-plan method, (M2 ) use of eight arcs optimised simultaneously and (M3 ) M2 with monitor unit reduction. Friedman ANOVA comparison, with Nemenyi's procedures, was used in the statistical analysis of the results. Results: The dosimetric results obtained for the planning target volume and for most OARs do not differ statistically between methods. The M3 method was characterized by the lowest numbers of monitor units (3259 MU vs. 4450 MU for M1 and 4216 MU for M2 ) and, in general, the lowest complexity. The variability of the monitor units from control points was almost half for M3 than M1 and M2 (i.e. 0.33 MU vs . 0.61 MU for M1 and 0.58 for M2 ). Analysing the relationship between the dose distributions obtained for the plans and their complexity, the best result was observed for the M3 method. Conclusion: The use of eight simultaneously optimised arcs with MU reduction allows to obtain VMAT-TMI plans that are characterized by the lowest complexity, with dose distributions comparable to the plans generated by other methods. … (more)
- Is Part Of:
- Physica medica. Volume 75(2020)
- Journal:
- Physica medica
- Issue:
- Volume 75(2020)
- Issue Display:
- Volume 75, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 75
- Issue:
- 2020
- Issue Sort Value:
- 2020-0075-2020-0000
- Page Start:
- 26
- Page End:
- 32
- Publication Date:
- 2020-07
- Subjects:
- Total marrow irradiation -- Volumetric modulated arc therapy -- Treatment plan complexity -- Plan optimization -- Radiotherapy
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.05.018 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13446.xml