Clinical evaluation of a novel multibolus contrast agent injection protocol for thoraco-abdominal CT angiography: Assessment of homogeneity of arterial contrast enhancement. Issue 126 (May 2020)
- Record Type:
- Journal Article
- Title:
- Clinical evaluation of a novel multibolus contrast agent injection protocol for thoraco-abdominal CT angiography: Assessment of homogeneity of arterial contrast enhancement. Issue 126 (May 2020)
- Main Title:
- Clinical evaluation of a novel multibolus contrast agent injection protocol for thoraco-abdominal CT angiography: Assessment of homogeneity of arterial contrast enhancement
- Authors:
- Obmann, Markus M.
Gehweiler, Julian
Schindera, Sebastian T.
Janetzki, Julia
Boll, Daniel T.
Benz, Matthias R. - Abstract:
- Highlights: A multibolus injection for long-range CTA was established in patients. A multibolus injection provides a plateau of homogenous arterial enhancement. Arterial attenuation is more homogenous than in a single-bolus injection. In aortic dissections attenuation differences between lumina are reduced. Abstract: Purpose: To evaluate the in vivo feasibility of a multibolus contrast agent (CA) injection protocol with a reduced CA volume for thoraco-abdominal CT angiography (CTA) and to compare it to a single-bolus CA injection protocol. Method: 63 patients who underwent CTA with the multibolus protocol (60 ml CA) were divided in two groups either without (group 1, n = 48) or with (group 2, n = 15) aortic dissection. The aortic contrast enhancement was measured in group 1 using manual ROI analysis (10 segments), as well as semi-automated linear attenuation profiles. A subgroup (n = 18) of group 1, who also underwent imaging with the single-bolus protocol (94 ml CA), was used to compare both protocols. In group 2, differences in attenuation of the true and the false lumen for both the single- and the multibolus protocol were assessed with ROI attenuation measurements in both lumina. Comparisons were made using Wilcoxon test. Results: Average attenuation was above 200 HU for 98 % of cases using the multibolus protocol. There was superior contrast homogeneity for the multibolus protocol with a lower standard deviation of attenuation values along the length of the scanHighlights: A multibolus injection for long-range CTA was established in patients. A multibolus injection provides a plateau of homogenous arterial enhancement. Arterial attenuation is more homogenous than in a single-bolus injection. In aortic dissections attenuation differences between lumina are reduced. Abstract: Purpose: To evaluate the in vivo feasibility of a multibolus contrast agent (CA) injection protocol with a reduced CA volume for thoraco-abdominal CT angiography (CTA) and to compare it to a single-bolus CA injection protocol. Method: 63 patients who underwent CTA with the multibolus protocol (60 ml CA) were divided in two groups either without (group 1, n = 48) or with (group 2, n = 15) aortic dissection. The aortic contrast enhancement was measured in group 1 using manual ROI analysis (10 segments), as well as semi-automated linear attenuation profiles. A subgroup (n = 18) of group 1, who also underwent imaging with the single-bolus protocol (94 ml CA), was used to compare both protocols. In group 2, differences in attenuation of the true and the false lumen for both the single- and the multibolus protocol were assessed with ROI attenuation measurements in both lumina. Comparisons were made using Wilcoxon test. Results: Average attenuation was above 200 HU for 98 % of cases using the multibolus protocol. There was superior contrast homogeneity for the multibolus protocol with a lower standard deviation of attenuation values along the length of the scan (p = 0.003), while average attenuation was higher for the single-bolus protocol (p = 0.002). Prolonged enhancement plateau lead to a more uniform opacification of the true and the false lumen in patients with aortic dissection using the multibolus protocol (p = 0.012). Conclusions: The multibolus protocol in thoraco-abdominal CTA is feasible in patients. It shows consistently high arterial enhancement with superior contrast homogeneity compared to a single-bolus protocol in patients with and without aortic dissection. … (more)
- Is Part Of:
- European journal of radiology. Issue 126(2020)
- Journal:
- European journal of radiology
- Issue:
- Issue 126(2020)
- Issue Display:
- Volume 126, Issue 126 (2020)
- Year:
- 2020
- Volume:
- 126
- Issue:
- 126
- Issue Sort Value:
- 2020-0126-0126-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-05
- Subjects:
- CT-angiography -- Scan range -- Contrast agent -- Injection protocol -- Bolus shaping
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2020.108957 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13435.xml