Phonocardiogram: A robust algorithm for generating synthetic signals and comparison with real life ones. (July 2020)
- Record Type:
- Journal Article
- Title:
- Phonocardiogram: A robust algorithm for generating synthetic signals and comparison with real life ones. (July 2020)
- Main Title:
- Phonocardiogram: A robust algorithm for generating synthetic signals and comparison with real life ones
- Authors:
- Tiam Kapen, Pascalin
Youssoufa, Mohamadou
Kouam Kouam, Serge Urbain
Foutse, Momo
Tchamda, André Rodrigue
Tchuen, Ghislain - Abstract:
- Highlights: A robust algorithm for generating synthetic PCG signals close to real life ones. The amplitude, S1S2 duration and heart rate of the real PCG used in the synthesis. The signals preprocessed with a second order Butterworth low pass filter of cutoff frequency of 500 Hz. Time domain correlations between the two sets of signals showed a good agreement. Percentage difference: 1.61% (heart rate), 2.27% (amplitude), 4.51% (S1S2 duration). Abstract: The work presented in this paper aims to develop and implement a robust algorithm for generating synthetic phonocardiogram (PCG) signals based on characteristics obtained from real life signals. The purpose of this work is to identify a few set of parameters that can be linked to the physiological state of the heart. The mathematical model used in the synthesis of the signal was based on three coupled ordinary differential equations (ODE) proposed by Jabloun et al. (2013). The amplitude, S2S1 duration, and heart rate of the real life PCG signals were extracted and used in the synthesis of the signals. The real life PCG signals were obtained from the MITHSDB and AADHSDB databases from Massachusetts Institute of Technology and Aalborg University respectively. The signals were preprocessed using a second order Butterworth low pass filter of cutoff frequency of 500 Hz to obtain cleaner versions. The system of equations was numerically solved with the fourth-order Runge-Kutta method. These synthetic PCG signals were then comparedHighlights: A robust algorithm for generating synthetic PCG signals close to real life ones. The amplitude, S1S2 duration and heart rate of the real PCG used in the synthesis. The signals preprocessed with a second order Butterworth low pass filter of cutoff frequency of 500 Hz. Time domain correlations between the two sets of signals showed a good agreement. Percentage difference: 1.61% (heart rate), 2.27% (amplitude), 4.51% (S1S2 duration). Abstract: The work presented in this paper aims to develop and implement a robust algorithm for generating synthetic phonocardiogram (PCG) signals based on characteristics obtained from real life signals. The purpose of this work is to identify a few set of parameters that can be linked to the physiological state of the heart. The mathematical model used in the synthesis of the signal was based on three coupled ordinary differential equations (ODE) proposed by Jabloun et al. (2013). The amplitude, S2S1 duration, and heart rate of the real life PCG signals were extracted and used in the synthesis of the signals. The real life PCG signals were obtained from the MITHSDB and AADHSDB databases from Massachusetts Institute of Technology and Aalborg University respectively. The signals were preprocessed using a second order Butterworth low pass filter of cutoff frequency of 500 Hz to obtain cleaner versions. The system of equations was numerically solved with the fourth-order Runge-Kutta method. These synthetic PCG signals were then compared with the real life PCG signals. The time domain correlations between the two sets of signals showed a good agreement between the two with values above 0.8 for all tested cases. The percentage differences in heart rate (beats per minutes), amplitude and S2S1 durations between the real life and synthesized PCG signals also showed a close match with percentage values as small as 1.61%, 2.27% and 4.51% for heart rate, amplitude and S2S1 duration respectively. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 60(2020)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 60(2020)
- Issue Display:
- Volume 60, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 60
- Issue:
- 2020
- Issue Sort Value:
- 2020-0060-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07
- Subjects:
- Phonocardiogram -- Synthetic signals -- Mathematical modeling -- Real life PCG signals -- Robust algorithm
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2020.101983 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13433.xml