Torsion and linear accuracy in intraoral scans obtained with different scanning principles. Issue 2 (April 2020)
- Record Type:
- Journal Article
- Title:
- Torsion and linear accuracy in intraoral scans obtained with different scanning principles. Issue 2 (April 2020)
- Main Title:
- Torsion and linear accuracy in intraoral scans obtained with different scanning principles
- Authors:
- Schmidt, Alexander
Benedickt, Christopher R.
Schlenz, Maximiliane A.
Rehmann, Peter
Wöstmann, Bernd - Abstract:
- Abstract: Purpose: Few investigations have examined the production of single restorations using intraoral scanners (IOS). Data on full-arch scans are rare, and data regarding torsion within the entire arch are very sparsely reported. Therefore, the aim of this study was to examine the deviations of torsion and linear distances in full-arch scans of three IOS based on different scanning principles. Methods: A cobalt-chrome-molybdenum alloy master model (CCMM) with four hemispheres was fabricated by laser sintering. The CCMM was digitized using a laboratory scanner (ATOS-Core/GOM) and scanned with three IOS (Omnicam/Sirona(OC); True Definition/3M(TD); TriosII/Cara-Version/Kulzer(TR)). All scan data were exported in a standard STL-file format and were analyzed with GOM Inspect software (V7.5/GOM). Torsion between the right and left side of the arch and linear accuracy (trueness and precision) were evaluated. After normality was confirmed, all data were subjected to parametric statistical analyses. Results: The torsion ranged from 0.07 ± 0.03°(OC) to 0.29 ± 0.14°(TD). Pairwise comparisons showed significant differences between the OC and TD scanners and between the TR and TD scanners. The linear distances ranged from 6 ± 5 μm(OC) to 298 ± 317 μm(TD). Significant differences were observed among all investigated IOS (p = 0.05). Conclusions: Although the highest torsion was observed for the TD scanner, it is still not clear whether the differences between the IOS are related to theAbstract: Purpose: Few investigations have examined the production of single restorations using intraoral scanners (IOS). Data on full-arch scans are rare, and data regarding torsion within the entire arch are very sparsely reported. Therefore, the aim of this study was to examine the deviations of torsion and linear distances in full-arch scans of three IOS based on different scanning principles. Methods: A cobalt-chrome-molybdenum alloy master model (CCMM) with four hemispheres was fabricated by laser sintering. The CCMM was digitized using a laboratory scanner (ATOS-Core/GOM) and scanned with three IOS (Omnicam/Sirona(OC); True Definition/3M(TD); TriosII/Cara-Version/Kulzer(TR)). All scan data were exported in a standard STL-file format and were analyzed with GOM Inspect software (V7.5/GOM). Torsion between the right and left side of the arch and linear accuracy (trueness and precision) were evaluated. After normality was confirmed, all data were subjected to parametric statistical analyses. Results: The torsion ranged from 0.07 ± 0.03°(OC) to 0.29 ± 0.14°(TD). Pairwise comparisons showed significant differences between the OC and TD scanners and between the TR and TD scanners. The linear distances ranged from 6 ± 5 μm(OC) to 298 ± 317 μm(TD). Significant differences were observed among all investigated IOS (p = 0.05). Conclusions: Although the highest torsion was observed for the TD scanner, it is still not clear whether the differences between the IOS are related to the scanning principle or to the scanning algorithm. Due to the high clinical relevance of full-arch restorations, future studies should consider torsion. Regarding linear accuracy, no general difference related to the scanning principles of the IOSs was observed. … (more)
- Is Part Of:
- Journal of prosthodontic research. Volume 64:Issue 2(2020)
- Journal:
- Journal of prosthodontic research
- Issue:
- Volume 64:Issue 2(2020)
- Issue Display:
- Volume 64, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 64
- Issue:
- 2
- Issue Sort Value:
- 2020-0064-0002-0000
- Page Start:
- 167
- Page End:
- 174
- Publication Date:
- 2020-04
- Subjects:
- Intraoral scanning torsion -- Intraoral scanning accuracy -- Trueness and precision
Prosthodontics -- Periodicals
Dentistry -- Periodicals
Prosthodontics -- Periodicals
Electronic journals
Computer network resources
617.6905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18831958 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jpor.2019.06.006 ↗
- Languages:
- English
- ISSNs:
- 1883-1958
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.915000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13422.xml