Mechanical performance, corrosion and tribological evaluation of a Co–Cr–Mo alloy processed by MIM for biomedical applications. (May 2020)
- Record Type:
- Journal Article
- Title:
- Mechanical performance, corrosion and tribological evaluation of a Co–Cr–Mo alloy processed by MIM for biomedical applications. (May 2020)
- Main Title:
- Mechanical performance, corrosion and tribological evaluation of a Co–Cr–Mo alloy processed by MIM for biomedical applications
- Authors:
- Herranz, Gemma
Berges, Cristina
Naranjo, Juan Alfonso
García, Cristina
Garrido, Ignacio - Abstract:
- Abstract: In this study, the processing parameters mechanical performance, corrosion and tribological evaluation of a low carbon content Co–Cr–Mo alloy are discussed. The production of parts using the Metal Injection Moulding (MIM) process is optimized, specifically concerning the rheological analysis of the prepared feedstocks, the optimum choice of the powder loading and the design of the debinding and sintering cycles. The mechanical properties as regards hardness, tensile strength and bending strength, as well as fatigue tests and wear characterization, are discussed for the full densified specimens obtained. Additionally, corrosion behaviour with the different methods and electrolytic solutions that simulate the biological environment has also been investigated. This approach allows us to confirm that the low-carbon cobalt alloy processed by MIM exhibits an adequate equilibrium between its mechanical and corrosion behaviour, with a notable performance during fatigue and wear tests. In the light of these findings, the use of this material for biomedical applications is discussed. Graphical abstract: Image 1 Highlights: MIM is confirmed an attractive manufacturing method for biocompatible cobalt alloys. A remarkable fatigue performance is determined in the sintered parts. Low carbon MIM parts show improvements in corrosion behaviour. The wear resistance exhibited allow its use as biomaterial.
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 105(2020)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 105(2020)
- Issue Display:
- Volume 105, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 105
- Issue:
- 2020
- Issue Sort Value:
- 2020-0105-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-05
- Subjects:
- Metal injection moulding -- Corrosion -- Mechanical properties -- Wear -- Biomedical components
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2020.103706 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13426.xml