A 3D printed porous titanium alloy rod with biogenic lamellar configuration for treatment of the early-stage femoral head osteonecrosis in sheep. (June 2020)
- Record Type:
- Journal Article
- Title:
- A 3D printed porous titanium alloy rod with biogenic lamellar configuration for treatment of the early-stage femoral head osteonecrosis in sheep. (June 2020)
- Main Title:
- A 3D printed porous titanium alloy rod with biogenic lamellar configuration for treatment of the early-stage femoral head osteonecrosis in sheep
- Authors:
- Wang, Cairu
Xie, Qingyun
Yang, Lanbo
Liu, Jinbiao
Liu, Da
Li, Zhiqiang
Gong, Kai
Yin, Li
Wang, Wei
Guo, Zheng
Zheng, Wei - Abstract:
- Abstract: There is no ideal implant for mechanical strut on early-stage osteonecrosis of the femoral head (ONFH) after core decompression. In this study, a biogenic trabecular porous titanium rod with lamellar configuration was designed and fabricated using selective laser melting technique. Early-stage ONFH of sheep induced by cryo-insult were dealt with core decompression combined with rod insertion (Rod group) and core decompression alone (CD group) after X-ray evaluation was used to assess the necrotic region one months after cryo-intervention. Bone integration and ingrowth of the two groups were investigated and compared. Early-stage ONFH intervened with the rod gained better bone ingrowth than CD 3 and 6 months after the intervention, as evidenced by radiographic, micro-CT and histological evaluation. X-ray images showed compact integration between rods and peripheral bone, evidenced by no radiolucent lines encircling the rods at 3 and 6 months. Micro-CT and histological images showed that the new bone had grown into the centre of rods along the metal at 3 months, whereas the new bone grew mainly at the periphery of the decompressive channel. Micro-CT analysis show that the ratios of bone volume to total volume (BV/TV) of volume of interest (VOI) in Rod group was 890.0% and 438.1% higher than CD group at 3 (0.198 ± 0.0094 VS 0.020 ± 0.0058, p < 0.05, n = 3) and 6 (0.226 ± 0.0166 VS 0.042 ± 0.0061, p < 0.05, n = 3) months respectively. Histological analysis showedAbstract: There is no ideal implant for mechanical strut on early-stage osteonecrosis of the femoral head (ONFH) after core decompression. In this study, a biogenic trabecular porous titanium rod with lamellar configuration was designed and fabricated using selective laser melting technique. Early-stage ONFH of sheep induced by cryo-insult were dealt with core decompression combined with rod insertion (Rod group) and core decompression alone (CD group) after X-ray evaluation was used to assess the necrotic region one months after cryo-intervention. Bone integration and ingrowth of the two groups were investigated and compared. Early-stage ONFH intervened with the rod gained better bone ingrowth than CD 3 and 6 months after the intervention, as evidenced by radiographic, micro-CT and histological evaluation. X-ray images showed compact integration between rods and peripheral bone, evidenced by no radiolucent lines encircling the rods at 3 and 6 months. Micro-CT and histological images showed that the new bone had grown into the centre of rods along the metal at 3 months, whereas the new bone grew mainly at the periphery of the decompressive channel. Micro-CT analysis show that the ratios of bone volume to total volume (BV/TV) of volume of interest (VOI) in Rod group was 890.0% and 438.1% higher than CD group at 3 (0.198 ± 0.0094 VS 0.020 ± 0.0058, p < 0.05, n = 3) and 6 (0.226 ± 0.0166 VS 0.042 ± 0.0061, p < 0.05, n = 3) months respectively. Histological analysis showed that the BV/TV of VOI in Rod group was 881.0% and 413.3% higher than CD group at 3 (0.206 ± 0.0102 VS 0.021 ± 0.0061, p < 0.05, n = 3) and 6 (0.231 ± 0.0156 VS 0.045 ± 0.0059, p < 0.05, n = 3) months respectively. The mechanical tests revealed that the maximum load of Rod group was 57.6% larger than CD group at 6 months (4505.25 ± 443.86 N VS 2858.25 ± 512.91 N, p < 0.05, n = 3). These favourable short-term results can provide insight on treatment of early-stage ONFH. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 106(2020)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 106(2020)
- Issue Display:
- Volume 106, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 106
- Issue:
- 2020
- Issue Sort Value:
- 2020-0106-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06
- Subjects:
- Osteonecrosis of the femoral head -- Porous titanium alloy -- Biogenic lamellar configuration -- Bone integration and ingrowth -- Sheep
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2020.103738 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13419.xml