Performance assessment of a new optimization system for robotic SBRT MLC-based plans. (March 2020)
- Record Type:
- Journal Article
- Title:
- Performance assessment of a new optimization system for robotic SBRT MLC-based plans. (March 2020)
- Main Title:
- Performance assessment of a new optimization system for robotic SBRT MLC-based plans
- Authors:
- Calusi, Silvia
Doro, Raffaela
Di Cataldo, Vanessa
Cipressi, Samantha
Francolini, Giulio
Bonucci, Ivano
Livi, Lorenzo
Masi, Laura - Abstract:
- Highlights: A critical analysis of plan quality evaluation was performed. Optimization with VOLO system highly reduce time required for plan optimization. Quality of VOLO-optimized plans is equivalent or higher than that of Sequential-optimized plans. Reliable plan quality comparison combining strong mathematical score and clinical evaluation. Abstract: Purpose: To assess the performance of a new optimization system, VOLO, for CyberKnife MLC-based SBRT plans in comparison with the existing Sequential optimizer. Methods: MLC-plans were created for 25 SBRT cases (liver, prostate, pancreas and spine) using both VOLO and Sequential. Monitor units (MU), delivery time (DT), PTV coverage, conformity (nCI), dose gradient (R50%) and OAR doses were used for comparison and combined to obtain a mathematical score (MS) of plan quality for each solution. MS strength was validated by changing parameter weights and by a blinded clinical plan evaluation. The optimization times (OT) and the average segment areas (SA) were also compared. Results: VOLO solutions offered significantly lower mean DT (−19%) and MU (−13%). OT were below 15 min for VOLO, whereas for Sequential, values spanned from 8 to 160 min. SAs were significantly larger for VOLO: on average 10 cm 2 versus 7 cm 2 . VOLO optimized plans achieved a higher MS than Sequential for all tested parameter combinations. PTV coverage and OAR sparing were comparable for both groups of solutions. Although slight differences in R50% and nCIHighlights: A critical analysis of plan quality evaluation was performed. Optimization with VOLO system highly reduce time required for plan optimization. Quality of VOLO-optimized plans is equivalent or higher than that of Sequential-optimized plans. Reliable plan quality comparison combining strong mathematical score and clinical evaluation. Abstract: Purpose: To assess the performance of a new optimization system, VOLO, for CyberKnife MLC-based SBRT plans in comparison with the existing Sequential optimizer. Methods: MLC-plans were created for 25 SBRT cases (liver, prostate, pancreas and spine) using both VOLO and Sequential. Monitor units (MU), delivery time (DT), PTV coverage, conformity (nCI), dose gradient (R50%) and OAR doses were used for comparison and combined to obtain a mathematical score (MS) of plan quality for each solution. MS strength was validated by changing parameter weights and by a blinded clinical plan evaluation. The optimization times (OT) and the average segment areas (SA) were also compared. Results: VOLO solutions offered significantly lower mean DT (−19%) and MU (−13%). OT were below 15 min for VOLO, whereas for Sequential, values spanned from 8 to 160 min. SAs were significantly larger for VOLO: on average 10 cm 2 versus 7 cm 2 . VOLO optimized plans achieved a higher MS than Sequential for all tested parameter combinations. PTV coverage and OAR sparing were comparable for both groups of solutions. Although slight differences in R50% and nCI were found, the parameters most affecting MS were MU and DT. VOLO solutions were selected in 80% of cases by both physicians with 88% inter-observer agreement. Conclusions: The good performance of the VOLO optimization system, together with the large reduction in OT, make it a useful tool to improve the efficiency of CK SBRT planning and delivery. The proposed methodology for comparing different planning solutions can be applied in other contexts. … (more)
- Is Part Of:
- Physica medica. Volume 71(2020)
- Journal:
- Physica medica
- Issue:
- Volume 71(2020)
- Issue Display:
- Volume 71, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 71
- Issue:
- 2020
- Issue Sort Value:
- 2020-0071-2020-0000
- Page Start:
- 31
- Page End:
- 38
- Publication Date:
- 2020-03
- Subjects:
- Plan quality -- Mathematical score -- Optimization algorithms -- Robotic SBRT -- Treatment planning technique comparison
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.02.009 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13416.xml