A centralized multi-objective model predictive control for a biventricular assist device: An in vitro evaluation. (May 2020)
- Record Type:
- Journal Article
- Title:
- A centralized multi-objective model predictive control for a biventricular assist device: An in vitro evaluation. (May 2020)
- Main Title:
- A centralized multi-objective model predictive control for a biventricular assist device: An in vitro evaluation
- Authors:
- Koh, V.C.A.
Pauls, J.P.
Wu, E.L.
Stevens, M.C.
Ho, Y.K.
Lovell, N.H.
Lim, E. - Abstract:
- Highlights: The proposed controller is superior than the constant speed setting. The proposed controller increased exercise capacity by increasing flow rate. The proposed controller avoided ventricular suction in extreme scenarios. The proposed controller avoided vascular congestion in extreme scenarios. Abstract: Control of a biventricular assist device (BiVAD) is more challenging than control of a left ventricular assist device due to the process interactions between control loops in a multi-input-multi-output system. Hence, a single centralized multi-objective model predictive controller (CMO-MPC) has been developed to control a BiVAD. The CMO-MPC aims to: 1) adapt pump flow rate according to the Frank-Starling mechanism, 2) avoid ventricular suction, and 3) avoid vascular congestion. The CMO-MPC was benchmarked against a constant-speed (CS) setting in exercise, postural change, and systemic vascular resistance change tests in a mock circulation loop. The CMO-MPC increased pump flow rate from 5.0 L/min to 7.6 L/min in the exercise scenario, which was higher than the pump flow rate in the CS setting (6.0 L/min). In the postural change test, right ventricular end diastolic pressure (RVEDP) decreased to a minimum at 0.1 mmHg and 2.0 mmHg in the CS setting and the CMO-MPC, respectively, indicating that the CMO-MPC could minimize the risk of ventricular suction (with higher minimum RVEDP than the CS setting) when there was a sudden decrease in venous return. In all tests, theHighlights: The proposed controller is superior than the constant speed setting. The proposed controller increased exercise capacity by increasing flow rate. The proposed controller avoided ventricular suction in extreme scenarios. The proposed controller avoided vascular congestion in extreme scenarios. Abstract: Control of a biventricular assist device (BiVAD) is more challenging than control of a left ventricular assist device due to the process interactions between control loops in a multi-input-multi-output system. Hence, a single centralized multi-objective model predictive controller (CMO-MPC) has been developed to control a BiVAD. The CMO-MPC aims to: 1) adapt pump flow rate according to the Frank-Starling mechanism, 2) avoid ventricular suction, and 3) avoid vascular congestion. The CMO-MPC was benchmarked against a constant-speed (CS) setting in exercise, postural change, and systemic vascular resistance change tests in a mock circulation loop. The CMO-MPC increased pump flow rate from 5.0 L/min to 7.6 L/min in the exercise scenario, which was higher than the pump flow rate in the CS setting (6.0 L/min). In the postural change test, right ventricular end diastolic pressure (RVEDP) decreased to a minimum at 0.1 mmHg and 2.0 mmHg in the CS setting and the CMO-MPC, respectively, indicating that the CMO-MPC could minimize the risk of ventricular suction (with higher minimum RVEDP than the CS setting) when there was a sudden decrease in venous return. In all tests, the CMO-MPC could adapt pump flow rate without resulting events of ventricular suction and vascular congestion. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 59(2020)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 59(2020)
- Issue Display:
- Volume 59, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 59
- Issue:
- 2020
- Issue Sort Value:
- 2020-0059-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-05
- Subjects:
- Frank-Starling mechanism -- Mock circulation loop -- Physiological control -- Ventricular suction -- Vascular congestion
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2020.101914 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13403.xml