Influence of alloying elements on cellular response and in-vitro corrosion behavior of titanium-molybdenum-chromium alloys for implant materials. Issue 4 (October 2020)
- Record Type:
- Journal Article
- Title:
- Influence of alloying elements on cellular response and in-vitro corrosion behavior of titanium-molybdenum-chromium alloys for implant materials. Issue 4 (October 2020)
- Main Title:
- Influence of alloying elements on cellular response and in-vitro corrosion behavior of titanium-molybdenum-chromium alloys for implant materials
- Authors:
- Mat-Baharin, Nor Haliza
Razali, Masfueh
Mohd-Said, Shahida
Syarif, Junaidi
Muchtar, Andanastuti - Abstract:
- Abstract: Purpose: Not all elements with β-stabilizing properties in titanium alloys are suitable for biomaterial applications, because corrosion and wear processes release the alloying elements to the surrounding tissue. Chromium and molybdenum were selected as the alloying element in this work as to find balance between the strength and modulus of elasticity of β-titanium alloys. This study aimed to investigate the effect of Titanium-10Molybdenum-10Chromium (Ti-10Mo-10Cr), Titanium-10Chromium (Ti-10Cr) and Titanium-10Molybdenum (Ti-10Mo) on the elemental leachability in tissue culture environment and their effect on the viability of human gingival fibroblasts (HGFs). Methods: Each alloy was immersed in growth medium for 0–21 days, and the elution was analyzed to detect the released metals. The elution was further used as the treatment medium and exposed to seeded HGFs overnight. The HGFs were also cultured directly to the titanium alloy for 1, 3 and 7 days. Cell viability was then determined. Results: Six metal elements were detected in the immersion of titanium alloys. Among these elements, molybdenum released from Ti-10Mo-10Cr had the highest concentration throughout the immersion period. Significant difference in the viability of fibroblast cells treated with growth medium containing metals and with direct exposure technique was not observed. The duration of immersion did not significantly affect cell viability. Nevertheless, cell viability was significantly affectedAbstract: Purpose: Not all elements with β-stabilizing properties in titanium alloys are suitable for biomaterial applications, because corrosion and wear processes release the alloying elements to the surrounding tissue. Chromium and molybdenum were selected as the alloying element in this work as to find balance between the strength and modulus of elasticity of β-titanium alloys. This study aimed to investigate the effect of Titanium-10Molybdenum-10Chromium (Ti-10Mo-10Cr), Titanium-10Chromium (Ti-10Cr) and Titanium-10Molybdenum (Ti-10Mo) on the elemental leachability in tissue culture environment and their effect on the viability of human gingival fibroblasts (HGFs). Methods: Each alloy was immersed in growth medium for 0–21 days, and the elution was analyzed to detect the released metals. The elution was further used as the treatment medium and exposed to seeded HGFs overnight. The HGFs were also cultured directly to the titanium alloy for 1, 3 and 7 days. Cell viability was then determined. Results: Six metal elements were detected in the immersion of titanium alloys. Among these elements, molybdenum released from Ti-10Mo-10Cr had the highest concentration throughout the immersion period. Significant difference in the viability of fibroblast cells treated with growth medium containing metals and with direct exposure technique was not observed. The duration of immersion did not significantly affect cell viability. Nevertheless, cell viability was significantly affected after 1 and 7 days of exposure, when the cells were grown directly onto the alloy surfaces. Conclusions: Within the limitation of this study, the newly developed β-titanium alloys are non-cytotoxic to human gingival fibroblasts. … (more)
- Is Part Of:
- Journal of prosthodontic research. Volume 64:Issue 4(2020)
- Journal:
- Journal of prosthodontic research
- Issue:
- Volume 64:Issue 4(2020)
- Issue Display:
- Volume 64, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 64
- Issue:
- 4
- Issue Sort Value:
- 2020-0064-0004-0000
- Page Start:
- 490
- Page End:
- 497
- Publication Date:
- 2020-10
- Subjects:
- Cytotoxicity -- β-titanium alloys -- Titanium alloys -- Leachable elements -- Titanium-chromium alloys
Prosthodontics -- Periodicals
Dentistry -- Periodicals
Prosthodontics -- Periodicals
Electronic journals
Computer network resources
617.6905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18831958 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jpor.2020.01.004 ↗
- Languages:
- English
- ISSNs:
- 1883-1958
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.915000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13391.xml