Image-analysis based readout method for biochip: Automated quantification of immunomagnetic beads, micropads and patient leukemia cell. (June 2020)
- Record Type:
- Journal Article
- Title:
- Image-analysis based readout method for biochip: Automated quantification of immunomagnetic beads, micropads and patient leukemia cell. (June 2020)
- Main Title:
- Image-analysis based readout method for biochip: Automated quantification of immunomagnetic beads, micropads and patient leukemia cell
- Authors:
- Uslu, Fatma
Icoz, Kutay
Tasdemir, Kasim
Doğan, Refika S.
Yilmaz, Bulent - Abstract:
- Highlights: Bright field optical microscope images processed to detect immunomagnetic beads, patient leukemia cells and micropads. No cell staining and no fluorescent labeling. Simple but time-efficient color, shape and size-based object detection methods incorporated. Patient response to chemotherapy was monitored. 95 % precision and 97 % recall for detecting patient leukemia cells were reported. Abstract: For diagnosing and monitoring the progress of cancer, detection and quantification of tumor cells is utmost important. Beside standard bench top instruments, several biochip-based methods have been developed for this purpose. Our biochip design incorporates micron size immunomagnetic beads together with micropad arrays, thus requires automated detection and quantification of not only cells but also the micropads and the immunomagnetic beads. The main purpose of the biochip is to capture target cells having different antigens simultaneously. In this proposed study, a digital image processing-based method to quantify the leukemia cells, immunomagnetic beads and micropads was developed as a readout method for the biochip. Color, size-based object detection and object segmentation methods were implemented to detect structures in the images acquired from the biochip by a bright field optical microscope. It has been shown that manual counting and flow cytometry results are in good agreement with the developed automated counting. Average precision is 85 % and average error rateHighlights: Bright field optical microscope images processed to detect immunomagnetic beads, patient leukemia cells and micropads. No cell staining and no fluorescent labeling. Simple but time-efficient color, shape and size-based object detection methods incorporated. Patient response to chemotherapy was monitored. 95 % precision and 97 % recall for detecting patient leukemia cells were reported. Abstract: For diagnosing and monitoring the progress of cancer, detection and quantification of tumor cells is utmost important. Beside standard bench top instruments, several biochip-based methods have been developed for this purpose. Our biochip design incorporates micron size immunomagnetic beads together with micropad arrays, thus requires automated detection and quantification of not only cells but also the micropads and the immunomagnetic beads. The main purpose of the biochip is to capture target cells having different antigens simultaneously. In this proposed study, a digital image processing-based method to quantify the leukemia cells, immunomagnetic beads and micropads was developed as a readout method for the biochip. Color, size-based object detection and object segmentation methods were implemented to detect structures in the images acquired from the biochip by a bright field optical microscope. It has been shown that manual counting and flow cytometry results are in good agreement with the developed automated counting. Average precision is 85 % and average error rate is 13 % for all images of patient samples, average precision is 99 % and average error rate is 1% for cell culture images. With the optimized micropad size, proposed method can reach up to 95 % precision rate for patient samples with an execution time of 90 s per image. … (more)
- Is Part Of:
- Micron. Volume 133(2020)
- Journal:
- Micron
- Issue:
- Volume 133(2020)
- Issue Display:
- Volume 133, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 133
- Issue:
- 2020
- Issue Sort Value:
- 2020-0133-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06
- Subjects:
- Biochip -- Image processing -- Leukemia cells -- Micropads -- Immunomagnetic beads -- Bright-field optical microscope
Microscopy -- Periodicals
Electron Probe Microanalysis -- Periodicals
Microscopy -- Periodicals
Microscopie -- Périodiques
Microscopy
Periodicals
502.82 - Journal URLs:
- http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.sciencedirect.com/science/journal/09684328 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.micron.2020.102863 ↗
- Languages:
- English
- ISSNs:
- 0968-4328
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5759.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13371.xml