Effect of size variation and gamma irradiation on thermoluminescence and photoluminescence characteristics of CaSO4:Eu micro- and nanophosphors. (May 2020)
- Record Type:
- Journal Article
- Title:
- Effect of size variation and gamma irradiation on thermoluminescence and photoluminescence characteristics of CaSO4:Eu micro- and nanophosphors. (May 2020)
- Main Title:
- Effect of size variation and gamma irradiation on thermoluminescence and photoluminescence characteristics of CaSO4:Eu micro- and nanophosphors
- Authors:
- Mandlik, Nandkumar T.
Sahare, P.D. PDS
Dhole, S.D. - Abstract:
- Abstract: Microcrystalline CaSO4 :Eu phosphor particles prepared by the acid re-crystallization method were grinded by ball-milling method and reduced to small particles of sizes ~50 nm, 200 nm, 400 nm and 5 μm. For comparison, nanocrystalline CaSO4 :Eu phosphor of size ~20 nm was also prepared by chemical coprecipitation method. The recorded photoluminescence emission and excitation spectra revealed that Eu is doped in CaSO4 :Eu in the form of Eu 2+ and Eu 3+ in all the samples of microcrystalline and nanocrystalline powders. The samples of CaSO4 :Eu, with different particle sizes, were irradiated with gamma rays over a range of doses ranging from 1 Gy to 100 kGy. The results of characterization by thermoluminescence method show that the intensity of the thermoluminescence peak for a given dose of gamma-rays decreases with the decrease in the particle size of CaSO4 :Eu. A comparison shows that CaSO4 :Eu of size 50 nm exhibited linear response between the thermoluminescence peak and the gamma-ray dose in the range of 1 Gy–10 kGy. This phosphor can, therefore, be used for the measurement of gamma ray dose in medical and industrial applications. A comparative study also showed that the sensitivity of thermoluminescence to gamma ray dose for the nanophosphor prepared by the ball milling technique is better than that of the nanophosphor prepared by chemical co-precipitation method. Highlights: Microcrystalline CaSO4 :Eu phosphor was prepared by the acid re-crystallizationAbstract: Microcrystalline CaSO4 :Eu phosphor particles prepared by the acid re-crystallization method were grinded by ball-milling method and reduced to small particles of sizes ~50 nm, 200 nm, 400 nm and 5 μm. For comparison, nanocrystalline CaSO4 :Eu phosphor of size ~20 nm was also prepared by chemical coprecipitation method. The recorded photoluminescence emission and excitation spectra revealed that Eu is doped in CaSO4 :Eu in the form of Eu 2+ and Eu 3+ in all the samples of microcrystalline and nanocrystalline powders. The samples of CaSO4 :Eu, with different particle sizes, were irradiated with gamma rays over a range of doses ranging from 1 Gy to 100 kGy. The results of characterization by thermoluminescence method show that the intensity of the thermoluminescence peak for a given dose of gamma-rays decreases with the decrease in the particle size of CaSO4 :Eu. A comparison shows that CaSO4 :Eu of size 50 nm exhibited linear response between the thermoluminescence peak and the gamma-ray dose in the range of 1 Gy–10 kGy. This phosphor can, therefore, be used for the measurement of gamma ray dose in medical and industrial applications. A comparative study also showed that the sensitivity of thermoluminescence to gamma ray dose for the nanophosphor prepared by the ball milling technique is better than that of the nanophosphor prepared by chemical co-precipitation method. Highlights: Microcrystalline CaSO4 :Eu phosphor was prepared by the acid re-crystallization method. By ball-milling method it reduced to small particles of sizes ~50 nm, 200 nm, 400 nm and 5 μm. CaSO4 :Eu phosphor of size ~20 nm was also prepared by chemical co-precipitation method. Thermoluminescence (TL) response of all samples have been studied from 1 Gy to 100 kGy gamma dose. CaSO4 :Eu nanophosphor of size 50 nm exhibited sublinear response in the range of 1 Gy–10 kGy. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 159(2020:May)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 159(2020:May)
- Issue Display:
- Volume 159 (2020)
- Year:
- 2020
- Volume:
- 159
- Issue Sort Value:
- 2020-0159-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-05
- Subjects:
- Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2020.109080 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13382.xml