Stereotactic body radiation therapy planning for liver tumors using functional images from dual-energy computed tomography. (April 2020)
- Record Type:
- Journal Article
- Title:
- Stereotactic body radiation therapy planning for liver tumors using functional images from dual-energy computed tomography. (April 2020)
- Main Title:
- Stereotactic body radiation therapy planning for liver tumors using functional images from dual-energy computed tomography
- Authors:
- Ohira, Shingo
Kanayama, Naoyuki
Toratani, Masayasu
Ueda, Yoshihiro
Koike, Yuhei
Karino, Tsukasa
Shunsuke, Ono
Miyazaki, Masayoshi
Koizumi, Masahiko
Teshima, Teruki - Abstract:
- Highlights: This study proposes a functional image based SBRT planning for liver tumors. The normalized iodine density map from DECT showed strong correlation with FIB-4. The proposed method could reduce doses to the high functional liver volume. The target coverage was comparable with the standard clinical plan. Abstract: Purpose: This study aimed to generate a functional image of the liver using dual-energy computed tomography (DECT) and a functional-image-based stereotactic body radiation therapy plan to minimize the dose to the volume of the functional liver ( V fl ). Material and methods: A normalized iodine density (NID) map was generated for fifteen patients with liver tumors. The volume of liver with an NID < 0.46 was defined as V fl, and the ratio between V fl and the total volume of the liver (FLR) was calculated. The relationship between the FLR and Fibrosis-4 (FIB-4) was assessed. For patients with 15% < FLR < 85%, functional volumetric modulated-arc therapy plans (F-VMAT) were retrospectively generated to preserve V fl, and compared to the clinical plans (C-VMAT). Results: FLR showed a significantly strong correlation with FIB-4 ( r = −0.71, p < 0.01). For ten generated F-VMAT plans, the dosimetric parameters of D99%, D50%, D1% and the conformity index were comparable to those of the C-VMAT ( p > 0.05). For V fl, F-VMAT plans achieved lower V5Gy (122.4 ± 31.7 vs 181.1 ± 57.3 cc), V10Gy (44.4 ± 22.2 vs 98.2 ± 33.3 cc), V15Gy (22.6 ± 20.3 vs 49.8 ± 33.7 cc),Highlights: This study proposes a functional image based SBRT planning for liver tumors. The normalized iodine density map from DECT showed strong correlation with FIB-4. The proposed method could reduce doses to the high functional liver volume. The target coverage was comparable with the standard clinical plan. Abstract: Purpose: This study aimed to generate a functional image of the liver using dual-energy computed tomography (DECT) and a functional-image-based stereotactic body radiation therapy plan to minimize the dose to the volume of the functional liver ( V fl ). Material and methods: A normalized iodine density (NID) map was generated for fifteen patients with liver tumors. The volume of liver with an NID < 0.46 was defined as V fl, and the ratio between V fl and the total volume of the liver (FLR) was calculated. The relationship between the FLR and Fibrosis-4 (FIB-4) was assessed. For patients with 15% < FLR < 85%, functional volumetric modulated-arc therapy plans (F-VMAT) were retrospectively generated to preserve V fl, and compared to the clinical plans (C-VMAT). Results: FLR showed a significantly strong correlation with FIB-4 ( r = −0.71, p < 0.01). For ten generated F-VMAT plans, the dosimetric parameters of D99%, D50%, D1% and the conformity index were comparable to those of the C-VMAT ( p > 0.05). For V fl, F-VMAT plans achieved lower V5Gy (122.4 ± 31.7 vs 181.1 ± 57.3 cc), V10Gy (44.4 ± 22.2 vs 98.2 ± 33.3 cc), V15Gy (22.6 ± 20.3 vs 49.8 ± 33.7 cc), V20Gy (11.6 ± 14.1 vs 24.9 ± 25.1 cc), and D mean (3.9 ± 2.3 vs 5.8 ± 3.0 Gy) values than the C-VMAT plans ( p < 0.01). Conclusions: The functional image derived from DECT was successfully used, allowing for a reduction in the dose to the V fl without compromising target coverage. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 145(2020)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 145(2020)
- Issue Display:
- Volume 145, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 145
- Issue:
- 2020
- Issue Sort Value:
- 2020-0145-2020-0000
- Page Start:
- 56
- Page End:
- 62
- Publication Date:
- 2020-04
- Subjects:
- SBRT -- Liver -- DECT -- Fibrosis -- Function
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2019.12.002 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13382.xml