Partial breast irradiation with the 1.5 T MR-Linac: First patient treatment and analysis of electron return and stream effects. (April 2020)
- Record Type:
- Journal Article
- Title:
- Partial breast irradiation with the 1.5 T MR-Linac: First patient treatment and analysis of electron return and stream effects. (April 2020)
- Main Title:
- Partial breast irradiation with the 1.5 T MR-Linac: First patient treatment and analysis of electron return and stream effects
- Authors:
- Nachbar, Marcel
Mönnich, David
Boeke, Simon
Gani, Cihan
Weidner, Nicola
Heinrich, Vanessa
lo Russo, Monica
Livi, Lorenzo
Winter, Jasmin
Tsitsekidis, Savas
Dohm, Oliver
Thorwarth, Daniela
Zips, Daniel
De-Colle, Chiara - Abstract:
- Abstract: Introduction: External beam partial breast irradiation (PBI) provides equal oncological outcomes compared to whole breast irradiation when applied to patients with low risk tumours. Recently, linacs with an integrated magnetic resonance image-guidance system have become clinically available. Here we report the first-in-human PBI performed at the 1.5 T MR-Linac, with a focus on clinical feasibility and investigation of the air electron stream effect (ESE) and the electron return effect (ERE) in the presence of the 1.5 T magnetic field, which might influence the dose on the chin (out-of-field dose, due to the ESE), the skin and the lung/chest wall interface (in-field dose, ERE). Methods: A 59 years old patient affected by a 15 mm unifocal grade 1 carcinoma not special type of the right breast staged pT1c pN0 cM0 was planned and treated at Unity 1.5 T MR-Linac. To investigate the ERE and the ESE, an MR-Linac treatment plan was simulated without considering the 1.5 T B field using a research version of Monaco (V. 5.19.03). In vivo dosimetry was performed using Gafchromic® EBT3 films placed on top and underneath a 1 cm bolus which was placed on the patient's chin. The plans with and without 1.5 T magnetic field were compared in terms of dose to the chin, to the skin and to the interface lung/chest wall. Finally, the dose on the chin measured with the in vivo dosimetry was compared with the dose calculated by Monaco. Results: PBI using the 1.5 T MR-Linac was successfullyAbstract: Introduction: External beam partial breast irradiation (PBI) provides equal oncological outcomes compared to whole breast irradiation when applied to patients with low risk tumours. Recently, linacs with an integrated magnetic resonance image-guidance system have become clinically available. Here we report the first-in-human PBI performed at the 1.5 T MR-Linac, with a focus on clinical feasibility and investigation of the air electron stream effect (ESE) and the electron return effect (ERE) in the presence of the 1.5 T magnetic field, which might influence the dose on the chin (out-of-field dose, due to the ESE), the skin and the lung/chest wall interface (in-field dose, ERE). Methods: A 59 years old patient affected by a 15 mm unifocal grade 1 carcinoma not special type of the right breast staged pT1c pN0 cM0 was planned and treated at Unity 1.5 T MR-Linac. To investigate the ERE and the ESE, an MR-Linac treatment plan was simulated without considering the 1.5 T B field using a research version of Monaco (V. 5.19.03). In vivo dosimetry was performed using Gafchromic® EBT3 films placed on top and underneath a 1 cm bolus which was placed on the patient's chin. The plans with and without 1.5 T magnetic field were compared in terms of dose to the chin, to the skin and to the interface lung/chest wall. Finally, the dose on the chin measured with the in vivo dosimetry was compared with the dose calculated by Monaco. Results: PBI using the 1.5 T MR-Linac was successfully performed with a 7 MV photon 7-beams IMRT step-and-shoot plan. The treatment was well tolerated, the patient developed a slight acute toxicity, i.e. breast skin erythema and breast oedema CTC V.4 grade 1. The plan with 1.5 T magnetic field documented a fractional dose of 0.17 Gy in the chin area (2.6 Gy in 15 fractions), which was reduced to 0.05 Gy (0.75 in 15 fractions) by the presence of 1 cm bolus. The simulated plan without magnetic field showed a dose reduced by 2.3 Gy in the chin area. With the in vivo dosimetry a fractional dose of, respectively, 0.12 Gy and 0.034 Gy on top and underneath the bolus were measured (1.8 and 0.51 Gy in 15 fractions). The plan with 1.5 T magnetic field showed a skin D2 of 40 Gy and a skin V35 of 40.2%, which were reduced to, respectively, 39.7 Gy and 24.9% in the simulation without magnetic field. At the interface lung/chest there were no differences in DVH statistics. Conclusion: PBI with the 1.5 T MR-Linac was performed for the first time. ESE is accurately calculated by the treatment planning system, can be effectively reduced with a 1 cm bolus and is comparable to dose of cone beam-CT based position verification. The additional dose caused by ERE is not associated with an increased risk of acute toxicity. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 145(2020)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 145(2020)
- Issue Display:
- Volume 145, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 145
- Issue:
- 2020
- Issue Sort Value:
- 2020-0145-2020-0000
- Page Start:
- 30
- Page End:
- 35
- Publication Date:
- 2020-04
- Subjects:
- Partial breast irradiation -- MR-Linac -- Electron stream effect -- Electron return effect
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2019.11.025 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13382.xml