Free-to-use DIR solutions in radiotherapy: Benchmark against commercial platforms through a contour-propagation study. (June 2020)
- Record Type:
- Journal Article
- Title:
- Free-to-use DIR solutions in radiotherapy: Benchmark against commercial platforms through a contour-propagation study. (June 2020)
- Main Title:
- Free-to-use DIR solutions in radiotherapy: Benchmark against commercial platforms through a contour-propagation study
- Authors:
- Scaggion, A.
Fiandra, C.
Loi, G.
Vecchi, C.
Fusella, M. - Abstract:
- Highlights: Three DIR algorithms available in the open 3D-slicer platform were tested. A contour-propagation study relevant for radiotherapy proposes was conducted. Four different anthropomorphic digital phantoms were used. Performance were benchmarked against recommended tolerances. Reference values from a large population-based study were taken as comparison. Abstract: Purpose: A contour propagation study has been conducted to benchmark three algorithms for Deformable Image Registration (DIR) freely available online against well-established commercial solutions. Methods: ElastiX, BRAINS and Plastimach, available as modules in the open source platform 3DSlicer, were tested as the recent AAPM Task group 132 guidelines proposes. The overlap of the DIR-mapped ROIs in four computational anthropomorphic phantoms was measured. To avoid bias every algorithm was left to run without any human interaction nor particular registration strategy. The accuracy of the algorithms was measured using the Dice Similarity Coefficient (DSC) and Mean Distance to Conformity (MDC) metrics. The registration quality was compared to the recommended geometrical accuracy suggested by AAPM TG132 and to the results of a large population-based study performed with commercial DIR solutions. Results: The considered free-to-use DIR solutions generally meet acceptable accuracy and good overlap (DSC > 0.85). Mild failures (DSC < 0.75) were detected only for the smallest structures. In case of extremely severeHighlights: Three DIR algorithms available in the open 3D-slicer platform were tested. A contour-propagation study relevant for radiotherapy proposes was conducted. Four different anthropomorphic digital phantoms were used. Performance were benchmarked against recommended tolerances. Reference values from a large population-based study were taken as comparison. Abstract: Purpose: A contour propagation study has been conducted to benchmark three algorithms for Deformable Image Registration (DIR) freely available online against well-established commercial solutions. Methods: ElastiX, BRAINS and Plastimach, available as modules in the open source platform 3DSlicer, were tested as the recent AAPM Task group 132 guidelines proposes. The overlap of the DIR-mapped ROIs in four computational anthropomorphic phantoms was measured. To avoid bias every algorithm was left to run without any human interaction nor particular registration strategy. The accuracy of the algorithms was measured using the Dice Similarity Coefficient (DSC) and Mean Distance to Conformity (MDC) metrics. The registration quality was compared to the recommended geometrical accuracy suggested by AAPM TG132 and to the results of a large population-based study performed with commercial DIR solutions. Results: The considered free-to-use DIR solutions generally meet acceptable accuracy and good overlap (DSC > 0.85). Mild failures (DSC < 0.75) were detected only for the smallest structures. In case of extremely severe deformations acceptable accuracy was not met (MDC > 3 mm). The morphing capability of the tested algorithms equals those of commercial systems when the user interaction is avoided. Underperformances were detected only in cases where a specific registration strategy is mandatory to obtain a satisfying match. Conclusions: All of the considered algorithms show performances not inferior to previously published data and have the potential to be good candidates for use in the clinical routine. The results and conclusions only apply to the considered phantoms and should not be considered to be generally applicable and extendable to patient cases. … (more)
- Is Part Of:
- Physica medica. Volume 74(2020)
- Journal:
- Physica medica
- Issue:
- Volume 74(2020)
- Issue Display:
- Volume 74, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 74
- Issue:
- 2020
- Issue Sort Value:
- 2020-0074-2020-0000
- Page Start:
- 110
- Page End:
- 117
- Publication Date:
- 2020-06
- Subjects:
- Deformable image registration -- Radiotherapy -- Open source
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.05.011 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13356.xml