His bundle pacing for newly acquired pacing needs in patients implanted with a subcutaneous implantable cardioverter defibrillator: A feasibility study based on the automated screening score and clinical cases. (29th May 2020)
- Record Type:
- Journal Article
- Title:
- His bundle pacing for newly acquired pacing needs in patients implanted with a subcutaneous implantable cardioverter defibrillator: A feasibility study based on the automated screening score and clinical cases. (29th May 2020)
- Main Title:
- His bundle pacing for newly acquired pacing needs in patients implanted with a subcutaneous implantable cardioverter defibrillator: A feasibility study based on the automated screening score and clinical cases
- Authors:
- Gauthey, Anaïs
Calle, Simon
Accinelli, Stefano
Depuydt, Philippe
Garnir, Quentin
Scavée, Christophe
Marchandise, Sébastien
Wauters, Aurélien
Bordachar, Pierre
de Pooter, Jan
de Waroux, Jean‐Benoît le Polain - Abstract:
- Abstract: Introduction: Management of subcutaneous implantable cardioverter defibrillator (S‐ICD) patients with newly acquired pacing needs remains problematic. His bundle pacing (HBP) allows for cardiac pacing without significant changes in the QRS morphology. We hypothesized that HBP does not alter S‐ICD sensing and functions. Methods: Twenty consecutive patients were implanted with a HB pacemaker. Among them, 17 demonstrated successful His recruitment and were prospectively screened with the automated screening tool (AST). Results of screenings performed immediately after implant and during follow‐up, during intrinsic rhythm and while pacing from all available pacing configurations, were compared using the AST score. Positive‐screening tests were defined by greater than or equal to 1 positive vector. Results: Among the 17 patients successfully implanted (male: 41%; mean age: 73), 13 presented an indication of ventricular pacing and four of cardiac resynchronization. Absolute AST scores during both HBP (all configurations) and intrinsic rhythm were similar ( p : NS). Due to left bundle branch block correction, HBP resulted in higher number of positive vectors (AST ≥ 100). AST scores were higher during HBP when compared with right ventricular pacing (RVP) (primary vector: 272 [16; 648] vs 4.6 [0.8; 16.2]; P = .003; secondary vector: 569 [183; 1186] vs 1.5 [0.7; 8.3]; P < .0001; alternate vector: 44 [2;125] vs 4.8 [0.9; 9.3]; P = .02) and resulted in a much higher numberAbstract: Introduction: Management of subcutaneous implantable cardioverter defibrillator (S‐ICD) patients with newly acquired pacing needs remains problematic. His bundle pacing (HBP) allows for cardiac pacing without significant changes in the QRS morphology. We hypothesized that HBP does not alter S‐ICD sensing and functions. Methods: Twenty consecutive patients were implanted with a HB pacemaker. Among them, 17 demonstrated successful His recruitment and were prospectively screened with the automated screening tool (AST). Results of screenings performed immediately after implant and during follow‐up, during intrinsic rhythm and while pacing from all available pacing configurations, were compared using the AST score. Positive‐screening tests were defined by greater than or equal to 1 positive vector. Results: Among the 17 patients successfully implanted (male: 41%; mean age: 73), 13 presented an indication of ventricular pacing and four of cardiac resynchronization. Absolute AST scores during both HBP (all configurations) and intrinsic rhythm were similar ( p : NS). Due to left bundle branch block correction, HBP resulted in higher number of positive vectors (AST ≥ 100). AST scores were higher during HBP when compared with right ventricular pacing (RVP) (primary vector: 272 [16; 648] vs 4.6 [0.8; 16.2]; P = .003; secondary vector: 569 [183; 1186] vs 1.5 [0.7; 8.3]; P < .0001; alternate vector: 44 [2;125] vs 4.8 [0.9; 9.3]; P = .02) and resulted in a much higher number of positive vectors. Up to 90% of the patients had a positive‐screening test during HBP. This passing rate was higher when compared RVP (17%; P < .0001). Conclusion: HBP restores normal intrinsic conduction and minimally modifies the surface electrocardiograph and subcutaneous electrograms. When ventricular pacing is needed, HBP might represent an ideal pacing option for patients implanted with a S‐ICD. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 31:Number 7(2020)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 31:Number 7(2020)
- Issue Display:
- Volume 31, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 7
- Issue Sort Value:
- 2020-0031-0007-0000
- Page Start:
- 1793
- Page End:
- 1800
- Publication Date:
- 2020-05-29
- Subjects:
- combination of devices -- feasibility -- His bundle pacing -- pacemaker -- subcutaneous implantable cardioverter defibrillator
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14566 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13365.xml