Experimental verification the electron return effect around spherical air cavities for the MR‐Linac using Monte Carlo calculation. Issue 6 (28th March 2020)
- Record Type:
- Journal Article
- Title:
- Experimental verification the electron return effect around spherical air cavities for the MR‐Linac using Monte Carlo calculation. Issue 6 (28th March 2020)
- Main Title:
- Experimental verification the electron return effect around spherical air cavities for the MR‐Linac using Monte Carlo calculation
- Authors:
- Shortall, J.
Vasquez Osorio, E.
Aitkenhead, A.
Berresford, J.
Agnew, J.
Budgell, G.
Chuter, R.
McWilliam, A.
Kirkby, K.
Mackay, R.
van Herk, M. - Abstract:
- Abstract : Purpose: Dose deposition around unplanned air cavities during magnetic resonance‐guided radiotherapy (MRgRT) is influenced by the electron return effect (ERE). This is clinically relevant for gas forming close to or inside organs at risk (OARs) that lie in the path of a single beam, for example, intestinal track during pelvic treatment. This work aims to verify Monte Carlo calculations that predict the dosimetric effects of ERE around air cavities. For this, we use GafChromic EBT3 film inside poly‐methyl methacrylate (PMMA) –air phantoms. Method: Four PMMA phantoms were produced. Three of the phantoms contained centrally located spherical air cavities (0.5, 3.5, 7.5 cm diameter), and one phantom contained no air. The phantoms were split to sandwich GafChromic EBT3 film in the center. The phantoms were irradiated on an Elekta Unity system using a single 10 × 10 cm 2 7‐MV photon beam under the influence of a 1.5‐T transverse magnetic field. The measurements were replicated using the Elekta Monaco treatment planning system (TPS). Gamma analysis with pass criteria 3%/3 mm was used to compare the measured and calculated dose distributions. We also consider 3%/2 mm, 2%/3 mm, and 2%/2 mm pass criteria for interest. Results: The gamma analysis showed that >95% of the points agreed between the TPS‐calculated and measured dose distributions, using 3%/3 mm criteria. The phantom containing the largest air cavity had the lowest agreement, with most of the disagreeing pointsAbstract : Purpose: Dose deposition around unplanned air cavities during magnetic resonance‐guided radiotherapy (MRgRT) is influenced by the electron return effect (ERE). This is clinically relevant for gas forming close to or inside organs at risk (OARs) that lie in the path of a single beam, for example, intestinal track during pelvic treatment. This work aims to verify Monte Carlo calculations that predict the dosimetric effects of ERE around air cavities. For this, we use GafChromic EBT3 film inside poly‐methyl methacrylate (PMMA) –air phantoms. Method: Four PMMA phantoms were produced. Three of the phantoms contained centrally located spherical air cavities (0.5, 3.5, 7.5 cm diameter), and one phantom contained no air. The phantoms were split to sandwich GafChromic EBT3 film in the center. The phantoms were irradiated on an Elekta Unity system using a single 10 × 10 cm 2 7‐MV photon beam under the influence of a 1.5‐T transverse magnetic field. The measurements were replicated using the Elekta Monaco treatment planning system (TPS). Gamma analysis with pass criteria 3%/3 mm was used to compare the measured and calculated dose distributions. We also consider 3%/2 mm, 2%/3 mm, and 2%/2 mm pass criteria for interest. Results: The gamma analysis showed that >95% of the points agreed between the TPS‐calculated and measured dose distributions, using 3%/3 mm criteria. The phantom containing the largest air cavity had the lowest agreement, with most of the disagreeing points lying inside the air cavity (dose to air region). Conclusions: The dose effects due to ERE around spherical air cavities are being calculated in the TPS with sufficient accuracy for clinical use. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 6(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 6(2020)
- Issue Display:
- Volume 47, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 6
- Issue Sort Value:
- 2020-0047-0006-0000
- Page Start:
- 2506
- Page End:
- 2515
- Publication Date:
- 2020-03-28
- Subjects:
- cancer -- dose -- experimental dosimetry -- IGRT -- Image‐guided radiotherapy -- MR‐guided radiotherapy -- MRgRT -- Radiotherapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14123 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13347.xml