The effect of stereotactic body radiotherapy (SBRT) using flattening filter‐free beams on cardiac implantable electronic devices (CIEDs) in clinical situations. Issue 6 (11th April 2020)
- Record Type:
- Journal Article
- Title:
- The effect of stereotactic body radiotherapy (SBRT) using flattening filter‐free beams on cardiac implantable electronic devices (CIEDs) in clinical situations. Issue 6 (11th April 2020)
- Main Title:
- The effect of stereotactic body radiotherapy (SBRT) using flattening filter‐free beams on cardiac implantable electronic devices (CIEDs) in clinical situations
- Authors:
- Aslian, Hossein
Kron, Tomas
Watts, Troy
Akalanli, Cagla
Hardcastle, Nicholas
Lonski, Peta
Montaseri, Atousa
Hay, Barry
Korte, James
Berk, Kemal
Longo, Francesco
Severgnini, Mara - Abstract:
- Abstract: Purpose: This study focused on determining risks from stereotactic radiotherapy using flattening filter‐free (FFF) beams for patients with cardiac implantable electronic device (CIEDs). Two strategies were employed: a) a retrospective analysis of patients with CIEDs who underwent stereotactic radiosurgery (SRS)/SBRT at the Peter MacCallum Cancer Centre between 2014 and 2018 and b) an experimental study on the impact of FFF beams on CIEDs. Methods: A retrospective review was performed. Subsequently, a phantom study was performed using 30 fully functional explanted CIEDs from two different manufacturers. Irradiation was carried out in a slab phantom with 6‐MV and 10‐MV FFF beams. First, a repetition‐rate test (RRT) with a range of beam pulse frequencies was conducted. Then, multifraction SBRT (48 Gy/4 Fx) and single‐fraction SBRT (28 Gy/1 Fx) treatment plans were used for lung tumors delivered to the phantom. Results: Between 2014 and 2018, 13 cases were treated with an FFF beam (6 MV, 1400 MU/min or 10 MV, 2400 MU/min), and 15 cases were treated with a flattening filter (FF) beam (6 MV, 600 MU/min). All the devices were positioned outside the treatment field at a distance of more than 5 cm, except for one case, and no failures were reported due to SBRT/SRS. In the phantom rep‐rate tests, inappropriate sensing occurred, starting at a rep‐rate of 1200 MU/min. Cardiac implantable electronic device anomalies during and after delivering VMAT‐SBRT with a 10‐MV FFF beamAbstract: Purpose: This study focused on determining risks from stereotactic radiotherapy using flattening filter‐free (FFF) beams for patients with cardiac implantable electronic device (CIEDs). Two strategies were employed: a) a retrospective analysis of patients with CIEDs who underwent stereotactic radiosurgery (SRS)/SBRT at the Peter MacCallum Cancer Centre between 2014 and 2018 and b) an experimental study on the impact of FFF beams on CIEDs. Methods: A retrospective review was performed. Subsequently, a phantom study was performed using 30 fully functional explanted CIEDs from two different manufacturers. Irradiation was carried out in a slab phantom with 6‐MV and 10‐MV FFF beams. First, a repetition‐rate test (RRT) with a range of beam pulse frequencies was conducted. Then, multifraction SBRT (48 Gy/4 Fx) and single‐fraction SBRT (28 Gy/1 Fx) treatment plans were used for lung tumors delivered to the phantom. Results: Between 2014 and 2018, 13 cases were treated with an FFF beam (6 MV, 1400 MU/min or 10 MV, 2400 MU/min), and 15 cases were treated with a flattening filter (FF) beam (6 MV, 600 MU/min). All the devices were positioned outside the treatment field at a distance of more than 5 cm, except for one case, and no failures were reported due to SBRT/SRS. In the phantom rep‐rate tests, inappropriate sensing occurred, starting at a rep‐rate of 1200 MU/min. Cardiac implantable electronic device anomalies during and after delivering VMAT‐SBRT with a 10‐MV FFF beam were observed. Conclusions: The study showed that caution should be paid to managing CIED patients when they undergo SBRT using FFF beams, as it is recommended by AAPM TG‐203. Correspondingly, it was found that for FFF beams although there is small risk from dose‐rate effects, delivering high dose of radiation with beam energy greater than 6 MV and high‐dose rate to CIEDs positioned in close vicinity of the PTV may present issues. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 21:Issue 6(2020)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 21:Issue 6(2020)
- Issue Display:
- Volume 21, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 6
- Issue Sort Value:
- 2020-0021-0006-0000
- Page Start:
- 121
- Page End:
- 131
- Publication Date:
- 2020-04-11
- Subjects:
- cardiac implantable electronic device (CIED) -- flattening filter‐free (FFF) beams -- stereotactic body radiotherapy (SBRT) -- volumetric‐modulated arc therapy (VMAT)
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12873 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13349.xml