Intelligent 4D CT sequence scanning (i4DCT): First scanner prototype implementation and phantom measurements of automated breathing signal‐guided 4D CT. Issue 6 (24th March 2020)
- Record Type:
- Journal Article
- Title:
- Intelligent 4D CT sequence scanning (i4DCT): First scanner prototype implementation and phantom measurements of automated breathing signal‐guided 4D CT. Issue 6 (24th March 2020)
- Main Title:
- Intelligent 4D CT sequence scanning (i4DCT): First scanner prototype implementation and phantom measurements of automated breathing signal‐guided 4D CT
- Authors:
- Werner, René
Sentker, Thilo
Madesta, Frederic
Schwarz, Annette
Vornehm, Marc
Gauer, Tobias
Hofmann, Christian - Abstract:
- Abstract : Purpose: Four‐dimensional (4D) computed tomography (CT) imaging is an essential part of current 4D radiotherapy treatment planning workflows, but clinical 4D CT images are often affected by artifacts. The artifacts are mainly caused by breathing irregularity during data acquisition, which leads to projection data coverage issues for currently available commercial 4D CT protocols. It was proposed to improve projection data coverage by online respiratory signal analysis and signal‐guided CT tube control, but related work was always theoretical and presented as pure in silico studies. The present work demonstrates a first CT prototype implementation along with respective phantom measurements for the recently introduced intelligent 4D CT (i4DCT) sequence scanning concept (https://doi.org/10.1002/mp.13632 ). Methods: Intelligent 4D CT was implemented on the Siemens SOMATOM go platform. Four‐dimensional CT measurements were performed using the CIRS motion phantom. Motion curves were programmed to systematically vary from regular to very irregular, covering typical irregular patterns that are known to result in image artifacts using standard 4D CT imaging protocols. Corresponding measurements were performed using i4DCT and routine spiral 4D CT with similar imaging parameters (e.g., mAs setting and gantry rotation time, retrospective ten‐phase reconstruction) to allow for a direct comparison of the image data. Results: Following technological implementation of i4DCT onAbstract : Purpose: Four‐dimensional (4D) computed tomography (CT) imaging is an essential part of current 4D radiotherapy treatment planning workflows, but clinical 4D CT images are often affected by artifacts. The artifacts are mainly caused by breathing irregularity during data acquisition, which leads to projection data coverage issues for currently available commercial 4D CT protocols. It was proposed to improve projection data coverage by online respiratory signal analysis and signal‐guided CT tube control, but related work was always theoretical and presented as pure in silico studies. The present work demonstrates a first CT prototype implementation along with respective phantom measurements for the recently introduced intelligent 4D CT (i4DCT) sequence scanning concept (https://doi.org/10.1002/mp.13632 ). Methods: Intelligent 4D CT was implemented on the Siemens SOMATOM go platform. Four‐dimensional CT measurements were performed using the CIRS motion phantom. Motion curves were programmed to systematically vary from regular to very irregular, covering typical irregular patterns that are known to result in image artifacts using standard 4D CT imaging protocols. Corresponding measurements were performed using i4DCT and routine spiral 4D CT with similar imaging parameters (e.g., mAs setting and gantry rotation time, retrospective ten‐phase reconstruction) to allow for a direct comparison of the image data. Results: Following technological implementation of i4DCT on the clinical CT scanner platform, 4D CT motion artifacts were significantly reduced for all investigated levels of breathing irregularity when compared to routine spiral 4D CT scanning. Conclusions: The present study confirms feasibility of fully automated respiratory signal‐guided 4D CT scanning by means of a first implementation of i4DCT on a CT scanner. The measurements thereby support the conclusions of respective in silico studies and demonstrate that respiratory signal‐guided 4D CT (here: i4DCT) is ready for integration into clinical CT scanners. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 6(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 6(2020)
- Issue Display:
- Volume 47, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 6
- Issue Sort Value:
- 2020-0047-0006-0000
- Page Start:
- 2408
- Page End:
- 2412
- Publication Date:
- 2020-03-24
- Subjects:
- 4D CT -- motion artifacts -- radiotherapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14106 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13346.xml