The potential of an optical surface tracking system in non‐coplanar single isocenter treatments of multiple brain metastases. Issue 6 (1st April 2020)
- Record Type:
- Journal Article
- Title:
- The potential of an optical surface tracking system in non‐coplanar single isocenter treatments of multiple brain metastases. Issue 6 (1st April 2020)
- Main Title:
- The potential of an optical surface tracking system in non‐coplanar single isocenter treatments of multiple brain metastases
- Authors:
- Swinnen, Ans C. C.
Öllers, Michel C.
Loon Ong, Chin
Verhaegen, Frank - Abstract:
- Abstract: To evaluate the accuracy of a commercial optical surface tracking (OST) system and to demonstrate how it can be implemented to monitor patient positioning during non‐coplanar single isocenter stereotactic treatments of brain metastases. A 3‐camera OST system was used (Catalyst HD™, C‐RAD) on a TruebeamSTx with a 6DoF couch. The setup accuracy and agreement between the OST system, and CBCT and kV‐MV imaging at couch angles 0° and 270°, respectively, were examined. Film measurements at 3 depths in the Rando‐Alderson phantom were performed using a single isocenter non‐coplanar VMAT plan containing 4 brain lesions. Setup of the phantom was performed with CBCT at couch 0° and subsequently monitored by OST at other couch angles. Setup data for 7 volunteers were collected to evaluate the accuracy and reproducibility of the OST system at couch angles 0°, 45°, 90°, 315°, and 270°. These results were also correlated to the couch rotation offsets obtained by a Winston‐Lutz (WL) test. The Rando‐Alderson phantom, as well as volunteers, were fixated using open face masks (Orfit). For repeated tests with the Rando‐Alderson phantom, deviations between rotational and translational isocenter corrections for CBCT and OST systems are always within 0.2° (pitch, roll, yaw), and 0.1mm and 0.5mm (longitudinal, lateral, vertical) for couch positions 0° and 270°, respectively. Dose deviations between the film and TPS doses in the center of the 4 lesions were −1.2%, −0.1%, −0.0%, and −1.9%.Abstract: To evaluate the accuracy of a commercial optical surface tracking (OST) system and to demonstrate how it can be implemented to monitor patient positioning during non‐coplanar single isocenter stereotactic treatments of brain metastases. A 3‐camera OST system was used (Catalyst HD™, C‐RAD) on a TruebeamSTx with a 6DoF couch. The setup accuracy and agreement between the OST system, and CBCT and kV‐MV imaging at couch angles 0° and 270°, respectively, were examined. Film measurements at 3 depths in the Rando‐Alderson phantom were performed using a single isocenter non‐coplanar VMAT plan containing 4 brain lesions. Setup of the phantom was performed with CBCT at couch 0° and subsequently monitored by OST at other couch angles. Setup data for 7 volunteers were collected to evaluate the accuracy and reproducibility of the OST system at couch angles 0°, 45°, 90°, 315°, and 270°. These results were also correlated to the couch rotation offsets obtained by a Winston‐Lutz (WL) test. The Rando‐Alderson phantom, as well as volunteers, were fixated using open face masks (Orfit). For repeated tests with the Rando‐Alderson phantom, deviations between rotational and translational isocenter corrections for CBCT and OST systems are always within 0.2° (pitch, roll, yaw), and 0.1mm and 0.5mm (longitudinal, lateral, vertical) for couch positions 0° and 270°, respectively. Dose deviations between the film and TPS doses in the center of the 4 lesions were −1.2%, −0.1%, −0.0%, and −1.9%. Local gamma evaluation criteria of 2%/2 mm and 3%/1 mm yielded pass rates of 99.2%, 99.2%, 98.6%, 89.9% and 98.8%, 97.5%, 81.7%, 78.1% for the 4 lesions. Regarding the volunteers, the mean translational and rotational isocenter shift values were (0.24 ± 0.09) mm and (0.15 ± 0.07) degrees. Largest isocenter shifts were found for couch angles 45˚ and 90˚, confirmed by WL couch rotation offsets. Patient monitoring during non‐coplanar VMAT treatments of brain metastases is feasible with submillimeter accuracy. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 21:Issue 6(2020)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 21:Issue 6(2020)
- Issue Display:
- Volume 21, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 6
- Issue Sort Value:
- 2020-0021-0006-0000
- Page Start:
- 63
- Page End:
- 72
- Publication Date:
- 2020-04-01
- Subjects:
- brain metastases -- non‐coplanar -- open face mask -- optical surface tracking -- stereotactic radiosurgery
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12866 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13337.xml