Utility of an index metacarpal cortical thickness application as an osteoporosis screen in distal radius fracture patients aged over 50. Issue 6 (12th March 2020)
- Record Type:
- Journal Article
- Title:
- Utility of an index metacarpal cortical thickness application as an osteoporosis screen in distal radius fracture patients aged over 50. Issue 6 (12th March 2020)
- Main Title:
- Utility of an index metacarpal cortical thickness application as an osteoporosis screen in distal radius fracture patients aged over 50
- Authors:
- Hymer, Isobel
Sivakumar, Brahman
Bindra, Randipsingh
Awal, Wasim
Robinson, Ann - Abstract:
- Abstract: Background: Following wrist fracture, it is desirable to identify patients with osteoporosis. A smartphone‐based application (BoneGauge) that uses second metacarpal cortical thickness ratio (2MCP) measured on X‐ray has been proposed. This study aims to validate this application using dual‐energy X‐ray absorptiometry scan in a cohort of patients with distal radius fractures. Methods: Thirty subjects aged 50 and over who sustained low‐energy fractures of the radius were recruited and measurements were completed by two independent observers using the application. Results: The interrater reliability as a screening tool was insufficient ( κ = 0.61). Using the 2MCP threshold of 60% for detection of osteopaenia or osteoporosis, we found insufficient correlation between the dual‐energy X‐ray absorptiometry scan and the two sets of readings using the application ( κ = 0.28 and 0.35, respectively). Conclusion: On the basis of these results, 2MCP of 60% is not sensitive enough to be used as a screening tool via a smartphone application for assessment of osteoporosis risk. Abstract : A smartphone‐based application (BoneGauge) that uses the second metacarpal cortical thickness ratio (2MCP) measured on X‐ray has been proposed. This study aims to validate this application using dual‐energy X‐ray absorptiometry scan in a cohort of patients with distal radius fractures.
- Is Part Of:
- ANZ journal of surgery. Volume 90:Issue 6(2020)
- Journal:
- ANZ journal of surgery
- Issue:
- Volume 90:Issue 6(2020)
- Issue Display:
- Volume 90, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 90
- Issue:
- 6
- Issue Sort Value:
- 2020-0090-0006-0000
- Page Start:
- 1067
- Page End:
- 1069
- Publication Date:
- 2020-03-12
- Subjects:
- metacarpal cortical ratio -- orthopaedic surgery -- osteopenia -- osteoporosis -- osteoporosis screening -- radius fracture
Surgery -- Periodicals
617.005 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/ans.15819 ↗
- Languages:
- English
- ISSNs:
- 1445-1433
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1566.878000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13339.xml